9 OUTLINE DRAWINGS
(e) MR-J4-700A4(-RJ)
2-φ6 mounting hole
Terminal
TE3
N- P3 P4
L1
L2 L3
P+
C
U
TE1
PE
TE3
TE1
TE2
PE
172
6
160
6
V W
TE2
L11 L21
Screw size: M4
Tightening torque: 1.2 [N•m]
Screw size: M4
Tightening torque: 1.2 [N•m]
Screw size: M3.5
Tightening torque: 0.8 [N•m]
Screw size: M4
Tightening torque: 1.2 [N•m]
Approx. 80
Approx. 28
6
Cooling fan
exhaust
With
MR-BAT6V1SET
Approx. 6
9 - 15
200
6
TE3
TE1
PE
Intake
Built-in regenerative resistor
lead terminal fixing screw
Screw size: M4
Tightening torque: 1.2 [N•m]
Mounting screw
Screw size: M5
Tightening torque: 3.24 [N•m]
Approx. 172
160
0.5
4-M5 screw
Mounting hole process drawing
[Unit: mm]
TE2
Mass: 6.5 [kg]