Mitsubishi Electric MR-J4 Instruction Manual page 747

Servo amplifers mr-j4-_a_(-rj), mr-j4-03a6(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

APPENDIX
App. 5.7.2 Specifications
Safety logic unit model
Voltage
Control circuit
Permissible
power supply
voltage fluctuation
Power supply
capacity
Compatible system
Shut-off input
Shut-off release input
Feedback input
Input type
Shut-off output
Output type
Delay time
setting
Functional safety
Standards certified
by CB
Response
performance
(when delay time
is set to 0s)
(Note 4)
Mean time to
dangerous failure
Safety
(MTTFd)
performance
Diagnosis
converge (DC avg)
Average
probability of
dangerous failures
per hour (PFH)
CE marking
Compliance to
standards
Ambient
Structure
temperature
Ambient humidity
Ambience
Environment
Altitude
Vibration
resistance
Mass
Note 1. Inrush current of approximately 1.5 A flows instantaneously when turning the control circuit power supply on. Select an
appropriate capacity of power supply considering the inrush current.
2. Power-on duration of the safety logic unit is 100,000 times.
3. _: in signal name indicates a number or axis name.
4. For the test pulse input, contact your local sales office.
[A]
4 points (2 point × 2 systems)
2 points (1 point × 2 systems) SRES_: (source/sink compatible) (Note 3)
2 points (1 point × 2 systems)
Photocoupler insulation, 24 V DC (external supply), internal limited resistance 5.4 kΩ
8 points (4 point × 2 systems)
Permissible current: 40 mA/1 output, Inrush current: 100 mA/1 output
A-axis: Select from 0 s, 1.4 s, 2.8 s, 5.6 s, 9.8 s, or 30.8 s.
B-axis: Select from 0 s, 1.4 s, 2.8 s, 9.8 s, or 30.8 s.
Accuracy: ±2%
EN ISO 13849-1 category 3 PL d, IEC 61508 SIL 2, EN 62061 SIL CL 2, and EN 61800-5-2 SIL 2
10 ms or less (STO input off → shut-off output off)
0 °C to 55 °C (non-freezing), storage: -20 °C to 65 °C (non-freezing)
90 %RH or less (non-condensing), storage: 90 %RH or less (non-condensing)
Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust, and dirt
5.9 m/s
[kg]
App. - 22
MR-J3-D05
24 V DC
24 V DC ± 10%
0.5 (Note 1, 2)
2 systems (A-axis, B-axis independent)
SDI_: (source/sink compatible) (Note 3)
TOF_: (source compatible) (Note 3)
STO_: (source compatible) (Note 3)
SDO_: (source/sink compatible) (Note 3)
Photocoupler insulation, open-collector type
STO, SS1 (IEC/EN 61800-5-2)
EMG STOP, EMG OFF IEC/EN 60204-1)
516 years
93.1%
-9
4.75 × 10
[1/h]
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
Natural-cooling, open (IP rating: IP 00)
Max. 1000 m above sea level
2
at 10 Hz to 55 Hz (directions of X, Y, and Z axes)
0.2 (including CN9 and CN10 connectors)