3. SIGNALS AND WIRING
3.1.1 200 V class
(1) For 3-phase 200 V AC to 240 V AC power supply of MR-J4-10A(-RJ) to MR-J4-350A(-RJ)
3-phase
200 V AC to
240 V AC
Forced stop 2
(Note 4)
Servo-on
Note 1. Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar
between P3 and P4. Refer to section 11.11 for details. Additionally, a power factor improving DC reactor and power factor
improving AC reactor cannot be used simultaneously.
2. Always connect between P+ and D terminals (factory-wired). When using the regenerative option, refer to section 11.2.
3. For the encoder cable, use of the option cable is recommended. For selecting cables, refer to "Servo Motor Instruction Manual
(Vol. 3)".
4. This diagram shows sink I/O interface. For source I/O interface, refer to section 3.9.3.
5. For connecting servo motor power wires, refer to "Servo Motor Instruction Manual (Vol. 3)".
6. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may
cause the forced stop deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not
required, slow the time to turn off the magnetic contactor.
7. Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
8. When not using the STO function, attach the short-circuit connector came with a servo amplifier.
9. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker. (Refer to
section 11.10.)
10. Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo amplifier may cause a malfunction.
11. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
Malfunction
RA1
(Note 6)
MCCB
MC
(Note 9)
(Note 1)
(Note 2)
(Note 7)
Main circuit power supply
24 V DC (Note 11)
(Note 8)
Short-circuit connector
(Packed with the servo amplifier)
OFF
ON
MC
EMG stop switch
Servo amplifier
CNP1
(Note 10)
L1
CNP3
U
L2
V
L3
W
N-
P3
P4
CNP2
P+
C
(Note 10)
D
CN2
L11
L21
CN1
EM2
CN1
SON
DOCOM
ALM
DICOM
CN8
3 - 3
MC
SK
Servo motor
(Note 5)
U
V
W
(Note 3)
Encoder
Encoder cable
24 V DC (Note 11)
Malfunction
RA1
Motor
M
(Note 4)