Do Forced Output (1-Axis/2-Axis/3-Axis) (B-15536 To 15538) - Mitsubishi Electric MELSERVO-J5 Series Sample Screen Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

DO Forced Output (1-axis/2-axis/3-axis) (B-15536 to 15538)

1
2
3
Outline
This screen is used to perform the forced output of output signals in the test operation mode.
Description
1.
Selects a DO Forced Output screen from the 1-axis servo amplifier and the multi-axis servo amplifiers,
and switches to the screen. The screen of a light blue switch is the screen which is currently being
displayed.
2.
Starts the DO forced output mode in the test operation mode. Touch the switch again to cancel the test
operation mode.
3.
Touch each switch to perform the forced output of the output signal. The lamp of the signal which is being
output lights. The supported output signals are different depending on each screen.
Screen
1-axis
2-axis
3-axis
Remarks
・ Switches which display another screen do not operate during the test operation mode.
・ Cycle the power supply of the servo amplifier after performing the test operation.
CN3-8, CN3-9, CN3-13 and CN3-15
CN3-11, CN3-12, CN3-24 and CN3-25
CN3-11, CN3-12, CN3-13, CN3-24 and CN3-25
37/128
Supported signals
BCN-P5999-1471-3c

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5-g

Table of Contents