8 How to program the adjustable frequency
drive
[2118]
Ext. 1 Feedback [Unit]
[2119]
Ext. 1 Output [%]
[2137]
Ext. 2 Reference [Unit]
[2138]
Ext. 2 Feedback [Unit]
[2139]
Ext. 2 Output [%]
[2157]
Ext. 3 Reference [Unit]
[2158]
Ext. 3 Feedback [Unit]
[2159]
Ext. Output [%]
[2230]
No-Flow Power
[2580]
Cascade Status
[2581]
Pump Status
NOTE!
Please consult the
0-21 Display Line 1.2 Small
Option:
8
[1662] *
Analog input 53
0-22 Display Line 1.3 Small
Option:
[1614] *
Motor Current
0-23 Display Line 2 Large
Option:
[1615] *
Frequency
0-24 Display Line 3 Large
Option:
[1652] *
Feedback [Unit]
0-37 Display Text 1
Range:
0 N/A*
[0 - 0 N/A]
8-12
The value of the feedback signal for extended closed-loop controller 1.
The value of the output from extended closed-loop controller 1.
The value of the reference for extended closed-loop controller 2.
The value of the feedback signal for extended closed-loop controller 2.
The value of the output from extended closed-loop controller 2.
The value of the reference for extended closed-loop controller 3.
The value of the feedback signal for extended closed-loop controller 3.
The value of the output from extended closed-loop controller 3.
The calculated no-flow power for the actual operating speed.
Status for the operation of the cascade controller.
Status for the operation of each individual pump controlled by the cascade controller.
VLT
®
AQUA Drive Programming Guide, MG.20.OX.YY
Function:
Select a variable for display in line 1, middle position.
The options are the same as those listed for par. 0-20
Function:
Select a variable for display in line 1, right position.
The options are the same as those listed for par. 0-20
Function:
Select a variable for display in line 2. The options are the same as those listed for par. 0-20
Line 1.1 Small
.
Function:
Select a variable for display in line 2. The options are the same as those listed for par. 0-20
Line 1.1 Small
.
Function:
In this parameter, it is possible to write an individual text string for display in the LCP or to be read
via serial communication. If to be displayed permanently, select Display Text 1 in par. 0-20
Line 1.1 Small
, par. 0-21
Line 2 Large
or par. 0-24
◀
character. Use the
cursor, it can be changed. Use the
can be inserted by placing the cursor between two characters and pressing
MG.20.M5.22 - VLT
for detailed information.
Display Line 1.1 Small
Display Line 1.1 Small
Display Line 1.2 Small
, par. 0-22
Display Line 1.3 Small
▲
Display Line 3 Large
. Use the
▶
and
buttons to move the cursor. When a character is highlighted by the
▲
▼
or
buttons on the LCP to change a character. A character
®
is a registered Danfoss trademark
®
VLT
AQUA Drive
Instruction Manual
.
.
Display
Display
Display
, par. 0-23
Display
▼
or
buttons on the LCP to change a
▲
▼
or
.
Need help?
Do you have a question about the vlt AQUA and is the answer not in the manual?