5�- Technical Features - Circutor CVM-C10 Instruction Manual

Power analyzer
Hide thumbs Also See for CVM-C10:
Table of Contents

Advertisement

CVM-C10
5�- TeChNICAL feATUReS
Rated voltage
frequency
Consumption
Installation category
Rated voltage
Consumption
Installation category
(1)
Only available for references
M5596100F0000.
Rated voltage (Un)
Voltage measurement margin
frequency measurement margin
Input impedance
Min� voltage measurement (Vstart)
Installation category
CVM-C10-fLeX
Nominal current (In)
Neutral current measurement
Current measurement margin
Maximum current, impulse < 1s
Min� current measurement (Istart)
Instruction Manual
AC Power supply
DC Power supply
105 ... 272 V
2 ... 6 W
M5591100F0000, M5592100F0000, M5592100F0V00, M5594200F00000 and
Voltage measurement circuit
Current measurement circuit
Measure through Rogowski sensors, see Table 2
CVM-C10-ITf
CVM-C10-ITf-IN
.../5A o .../1 A
CVM-C10-mV
CVM-C10-ITf-IN
.../5A o .../1 A
CVM-C10-ITf
CVM-C10-ITf-IN
2 ... 120% In
CVM-C10-mV
2 ... 120% In
CVM-C10-ITf
CVM-C10-ITf-IN
CVM-C10-mV
CVM-C10-ITf
CVM-C10-ITf-IN
CVM-C10-mV
~
95 ... 240 V
± 10%
50 ... 60 Hz
4 ... 6 VA
CAT III 300 V
± 10%
23 ... 109 V
CAT III 300 V
300 V
, 520 V
Ph-N
5 ... 120% Un
45 ... 65Hz
440 kΩ
10 V
CAT III 300 V
.../0.333 V
100 A
1.2 In
10 mA
0.25 A
6.66 mV
± 10%
(1)
3.5 ... 3 W
Ph-Ph
CVM-C10-MC
.../0.250 A
CVM-C10-fLeX
.../100 mV ~
CVM-C10-fLeX
.../100 mV ~
CVM-C10-MC
2 ... 120% In
CVM-C10-fLeX
0.2 ... 200% In
CVM-C10-MC
100 A
CVM-C10-fLeX
2 In
CVM-C10-MC
MC1
MC3
0.1 A
CVM-C10-fLeX
~
0.2 mV
87

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CVM-C10 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF