Parameters - ABB PST Installation And Maintenance Manual

Table of Contents

Advertisement

No
Type
Parameter
1
Read/Write
Setting Ie
2
Read/Write
Start Ramp
3
Read/Write
Stop Ramp
4
Read/Write
Init Volt
5
Read/Write
End Volt
6
Read/Write
Step Down
7
Read/Write
Current Lim
8
Read/Write
Kick Start
9
Read/Write
Kick Level
10
Read/Write
Kick Time
11
Read/Write
Start Range
12
Read/Write
Stop Range
13
Read/Write
Overload
14
Read/Write
OL Class
15
Read/Write
OL Class S
16
Read/Write
OL Class R
17
Read/Write
OL Op
18
Read/Write
Locked Rotor
19
Read/Write
Lock R Lev
20
Read/Write
Lock R Time
21
Read/Write
Lock R Op
22
Read/Write
Underload
23
Read/Write
Underl Lev
24
Read/Write
Underl Time
25
Read/Write
Underl Op
26
Read/Write
Phase Imb
27
Read/Write
Ph Imb Lev
28
Read/Write
Ph Imb Op
29
Read/Write
High I
30
Read/Write
High I Op
31
Read/Write
Phase Rev
32
Read/Write
Ph Rev Op
33
Read/Write
PTC
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Chapter 8 - Fieldbus communication (option)

8:1.3.8 Parameters

Description
Setting current
Time for start ramp
Time for stop ramp
Initial voltage for start ramp
End voltage for stop ramp
Voltage value to which the softstarter
shall step down at stop and where it
shall commence the stop ramp.
Level of the current limit.
Selection of Kick start
Level of Kick start if selected
Time for Kick start if selected
Selectable range for start ramp
Selectable range for stop ramp
Overload protection
Overload Class
Overload Class, Dual type, Start Class 10A, 10, 20, 30
Overload Class, Dual type, Run Class 10A, 10, 20, 30
Type of operation for overload
protection
Locked rotor protection
Trip level for locked rotor protection
Trip time for locked rotor protection
Type of operation for locked rotor
protection
Underload protection
Trip level for Underload protection
Trip time for Underload protection
Type of operation for Underload
protection
Phase imbalance protection
Trip level for phase imbalance
protection
Type of operation for phase imbalance
protection
High current protection
Type of operation for high current
protection
Phase reversal protection
Type of operation for phase reversal
protection
PTC protection
Range
0 – 3000 (*)
1 – 120
0 – 120
30 – 70
30 – 70
30 – 100
2.0 – 5.0
No, Yes
50 – 100
0.1 – 1.5
1-30s, 1-120s
0-30s, 0-120s)
No, Normal, Dual
10A, 10, 20, 30
Stop– M, Stop– A, Ind
No, Yes
3.0 – 8.0
0.2 – 10.0
Stop– M, Stop– A, Ind
No, Yes
0.4 – 0.8
1 – 30
Stop– M, Stop– A, Ind
No, Yes
10 – 80
Stop– M, Stop– A, Ind
No, Yes
Stop– M, Stop– A, Ind
No, Yes
Stop– M, Stop– A, Ind
No, Yes
Unit
Amp
Sec
Sec
%
%
%
x Ie
%
Sec
x Ie
Sec
x Ie
Sec
%
109
AC 1006.9 - 5/03