ABB PST Installation And Maintenance Manual page 110

Table of Contents

Advertisement

No
Type
Parameter
34
Read/Write
PTC Op
35
Read/Write
Ext ByPass
36
Read/Write
BP Fault Op
37
Read/Write
Warn I=High
38
Read/Write
Wa I=H Lev
39
Read/Write
Warn I=Low
40
Read/Write
Wa I=L Lev
41
Read/Write
Warn OL
42
Read/Write
Wa OL Lev
43
Read/Write
Warn SCR OL
44
Read/Write
Ph Loss Op
45
Read/Write
FB Fault Op
46
Read/Write
Freq F Op.
47
Read/Write
HS Temp Op
48
Read/Write
SCR SC Op
49
Read
In0
50
Read
In1
51
Read/Write
Relay K4
52
Read/Write
Relay K5
53
Read/Write
Relay K6
54
Read/Write
SW Outp V7
55
Read/Write
Event K4
56
Read/Write
Event K5
57
Read/Write
Event K6
58
Read/Write
Event V7
59
Read
Fieldb Ctrl
60
Read
Fieldb Type
61
Read
Fieldb Addr
110
AC 1006.9 - 5/03
Chapter 8 - Fieldbus communication (option)
Description
Type of operation for PTC protection
External By-pass contactor is used
Type of operation for by-pass monitor
protection
High current warning
Trip level for high current warning
Low current warning
Trip level for low current warning
Overload warning
Trip level for overload warning
SCR overload warning
Type of operation for phase loss fault
Type of operation for fieldbus fault
Type of operation for frequency fault
Type of operation for heat sink over
temperature fault
Type of operation for SCR short circuit
fault
Function of programmable input In0
Function of programmable input In1
Function of programmable relay output
K4
Function of programmable relay output
K5
Function of programmable relay output
K6
Function of programmable software
output V7
Different events to include for
signalling with K4 if "Event" is selected
Different events to include for
signalling with K5 if "Event" is selected
Different events to include for
signalling with K6 if "Event" is selected
Different events to include for
signalling with V7 if "Event" is selected
Control of the softstarter with fieldbus
Type of fieldbus
Fieldbus address
Range
Stop– M, Stop– A, Ind
No, Yes
Stop– M, Stop– A
No, Yes
0.5 – 5.0
No, Yes
0.4 – 1.0
No, Yes
40 – 99
No, Yes
Stop– M, Stop– A
Stop– M, Stop– A
Stop– M, Stop– A
Stop– M, Stop– A
Stop– M, Stop– A
None, Reset, Enable,
Jog, DOL-on, Start2
None, Reset, Enable,
Jog, DOL-on, Start3
Run, TOR, Event
Run, TOR, Event
Run, TOR, Event
Run, TOR, Event
0 – 65535, Bit mask see
separate description.
0 – 65535, Bit mask see
separate description.
0 – 65535, Bit mask see
separate description.
0 – 65535, Bit mask see
separate description.
No, Yes
AS-I, Other
0 – 1000
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Unit
x Ie
x Ie
%

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pstb

Table of Contents