Displaying LED Conditions

The same conditions monitored by the front panel LEDs can also be monitored by
the LED command. This command is most useful when the DSU/CSU is being
accessed remotely (see
Panel Emulation, no LEDs are shown on the PC's screen; you must use the Stat
command procedure described below to get LED information.
Procedure
To display LED conditions on the front panel screen:
3160-A2-GB21-90
Appendix G, Front Panel Emulation
NOTE:
The following procedure is an example only. Screen displays may vary
depending on the model of the DSU/CSU.
1. From the top-level menu screen, select Stat.
2. From the Status screen, press the
the screen.
3. From the Status screen, select LED.
Status:
Perf
TStat
F2
F1
4. From the Select LEDs screen, press the Function key that corresponds to T1
interface or the data port for which you want to display LEDs. Use the scroll
keys, if necessary.
Select LEDs:
T1
Prt1
F2
F1
If you chose T1, the LED Display screen lists the LED signals, two at a time,
on the second line. A vertical bar at the left of the LED name indicates the
condition is ON, while an underscore indicates the condition is Off.
LED Display:
_Test
_NetSig
F2
F1
February 2001
key until the LED selection appears on
LED
F3
Prt2
F3
F3