2. Installation
Figure 2-9.
Installing the Single –48 Vdc Power Supply
To install the DSU/CSU using a single source –48 Vdc SELV power supply, refer to
Figure 2-10, –48 Vdc Single Source Power Supply
procedure.
Procedure
To install the –48 Vdc single source power supply:
Figure 2-10. –48 Vdc Single Source Power Supply Pinouts
2-6
DSU/CSU POWER
PLUG
BLACK
1
RED
2
GREEN
3
WHITE
4
ORANGE
5
BLUE
6
+24 Vdc Power Supply Pinouts
1. Connect the black and red wires to the –48 Vdc return source.
2. Connect the green wire to a suitable ground.
3. Connect the orange and blue wires to the – 48 Vdc input source.
4. Cut the white wire off at the outer insulation.
5. Plug the power connector into the DSU/CSU.