Paradyne 3160-A3 Operator's Manual page 112

Paradyne acculink dsu / csu operator's guide 3160-a3, 3161-b3, 3164-a2, 3165-a2
Table of Contents

Advertisement

4. Maintenance
Table 4-3.
4-10
Performance Registers (2 of 2)
Register
Interval Description
LOFC
The loss of frame count for the
current interval. This is a count of
the number of times that an LOF is
declared. The maximum count is
255.
CSS
The number of controlled slip
(Not valid
seconds for the current interval.
for Port
registers.)
StEvnt
The status events register records
(Only valid
whether one or more of the
for User
following events have occurred at
registers.)
least once during the interval. The
event is identified by a letter as
follows:
Y – A Yellow Alarm signal has
been received on the network
interface.
L – Loss Of Signal has occurred
on the DTE Drop/Insert (DSX-1)
interface.
E – The Excessive Error Rate
threshold has been exceeded.
F – A Frame Synchronization Bit
Error has been detected.
V – A Bipolar Violation has been
detected.
If none of these events occurred
during the interval, StEvnt=none
will be displayed.
Complete
Bad line conditions or loopback
(Only valid
tests may prevent far-end port
for far-end
statistics from reaching the
port
DSU/CSU. This field indicates
registers.)
whether the 15-minute interval
contains 900 seconds of statistics.
If one or more seconds of far-end
statistics are missing, this field will
display Complete=No, otherwise it
will display Complete=Yes. This
field is only displayed when Far is
selected from the Prt n screen.
February 2001
Totals Description
The total loss of frame count for the
previous x hours, where x is
24 hours for aggregate performance
and 8 hours for port performance.
The total number of controlled slip
seconds for the previous x hours,
where x is 24 hours for aggregate
performance and 8 hours for port
performance.
N/A
N/A
3160-A2-GB21-90

Advertisement

Table of Contents
loading