Sending Test Patterns - Paradyne 3160-A3 Operator's Manual

Paradyne acculink dsu / csu operator's guide 3160-a3, 3161-b3, 3164-a2, 3165-a2
Table of Contents

Advertisement

Sending Test Patterns

Use the Send command to start transmission of a test pattern.
Only one test pattern can be active at a time on one port.
Test Pattern
combinations are identified by YES.
Procedure
To send a test pattern:
3160-A2-GB21-90
Combinations, lists the valid send test pattern combinations. Valid
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk
Lpbk
F1
F2
3. From the Patterns screen, select Send.
Patterns:
Abort
Send
F1
F2
4. From the Patterns Send screen, press F1 to send a QRSS pattern, F2 to send
a 1-in-8 pattern, F3 to send a 511 pattern.
Patterns: Send
QRSS
1in8
F1
F2
If you send a 1-in-8 pattern, skip Step 5.
5. From the Send screen, press the Function key that corresponds to network or
the port for which you want to send a test pattern. Use the scroll keys, if
necessary. (NET does not appear for the 511 pattern.)
Send: Name
NET
Prt1
F1
F2
February 2001
Ptrns
F3
Mon
F3
511
F3
Prt2
F3
4. Maintenance
Table 4-9, Valid Send
4-31

Advertisement

Table of Contents
loading

Table of Contents