Paradyne 3160-A3 Operator's Manual page 244

Paradyne acculink dsu / csu operator's guide 3160-a3, 3161-b3, 3164-a2, 3165-a2
Table of Contents

Advertisement

E. SNMP MIB Objects
Table E-1.
SNMP MIB to Front Panel Command Cross-Reference (2 of 3)
Front Panel Command
Stat–>LED–>Prtn:
DTR
CTS
RTS
Stat–>ID:
Ser
Mod
SRev
HRevCCA1
HRevCCA2
Test–>Rlpbk–>LLBUP
Test–>Rlpbk–>LLBDN
Test–>Rlpbk–>54UP–>Prt n
Test–>Rlpbk–>54DN–>Prt n
Test–>Rlpbk–>FT1UP–>Prt n
Test–>Rlpbk–>FT1DN–>Prt n
Test–>Lpbk–>LLB
Test–>Lpbk–>Abort–>LLB
Test–>Lpbk–>PLB
Test–>Lpbk–>Abort–>PLB
Test–>Lpbk–>DLB
Test–>Lpbk–>Abort–>DLB
Test–>Lpbk–>RLB
Test–>Lpbk–>Abort–>RLB
Test–>Lpbk–>DCLB–>Prt n
Test–>Lpbk–>Abort–>Lpbk–>Prt n
Test–>Lpbk–>DTLB–>Prt n
Test–>Lpbk–>Abort–>DTLB–>Prt n
Test–>Prtns–>Send–>QRSS–>NET
Test–>Prtns–>Abort–>Send–>NET
Test–>Prtns–>Send–>QRSS–>Prt n
Test–>Prtns–>Abort–>Send–>Prt n
Test–>Prtns–>Send–>1in8
Test–>Prtns–>Abort–>Send–>NET
Test–>Prtns–>Send–>511–>Prt n
Test–>Prtns–>Abort–>Send–>Prt n
E-30
SNMP MIB Object
Read:
rs232InSigState from rs232InSigName == dtr
rs232outSigState from rs232OutSigName == ctr
rs232InSigState from rs232InSigName == rts
Read the sysDescr object from the System Group
Set dsx1SendCode to dsx1SendLineCode
Set dsx1SendCode to dsx1SendResetCode
Set IfExtnsTestType for port n to testSendV54Up
Set IfExtnsTestType for port n to testSendV54Down
Set IfExtnsTestType for port n to testSendFT1UP
Set IfExtnsTestType for port n to testSendFT1Down
Set dsx1LoopbackConfig for Net T1 to dsx1LineLoop
Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop
Set dsx1LoopbackConfig for Net T1 to dsx1PayloadLoop
Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop
Set dsx1LoopbackConfig for DTE T1 to dsx1LineLoop
Set dsx1LoopbackConfig for DTE T1 to dsx1NoLoop
Set dsx1LoopbackConfig for DTE T1 to dsx1PayloadLoop
Set dsx1LoopbackConfig for DTE T1 to dsx1NoLoop
Set IfExtnsTestType for port n to testFullDuplexLoopBack
Set dsx1LoopbackConfig for port n to noTest
Set IfExtnsTestType for port n to testLoopDTLB
Set dsx1LoopbackConfig for port n to noTest
Set dsx1SendCode for Net T1 to dsx1SendQRSS
Set dsx1SendCode for Net T1 to dsx1SendNoCode
Set IfExtnsTestType for port n to testSendQRS
Set IfExtnsTestType for port n to noTest
Set dsx1SendCode for Net T1 to dsx1SendOtherTestPattern
Set dsx1SendCode for Net T1 to dsx1SendNoCode
Set IfExtnsTestType for port n to testSend511
Set IfExtnsTestType for port n to noTest
February 2001
3160-A2-GB21-90

Advertisement

Table of Contents
loading

Table of Contents