Setting Customer Identification - Paradyne 3160-A3 Operator's Manual

Paradyne acculink dsu / csu operator's guide 3160-a3, 3161-b3, 3164-a2, 3165-a2
Table of Contents

Advertisement

Setting Customer Identification

The customer identification is the only identity number you can change. It is used
to uniquely identify the DSU/CSU.
Procedure
To change the customer identification (CID):
3160-A2-GB21-90
1. From the top-level menu, press the
the screen.
2. Select Ctrl.
3. From the Control screen, press the
the screen.
4. Select CID.
Control:
Reset
CID
F2
F1
5. Use the
and
keys to position the cursor under the desired character.
You must enter a character before the
to the right.
CustID: xxxxxxxx
Up
Down
F2
F1
6. Enter the desired ID. Press F1 (Up) and F2 (Down) to scroll up and down
through the valid characters/numbers for the customer ID. Valid characters are
0 through 9, #, -, ., /, A to Z, and blank space. Press F3 (Save) to save the ID.
February 2001
key until the Ctrl selection appears on
key until the CID selection appears on
Passwd
F3
moves the cursor to the next space
Save
F3
3. Operation
3-11

Advertisement

Table of Contents