Table 1-1.
3160-A2-GB21-90
Standalone DSU/CSU Rear Panel Connectors
Name
POWER
AUX PORT
COM PORT
MODEM
NETWORK
DTE (Model 3160/3164)
CLOCK IN (Models
3160/3164)
PORTs 1–4
February 2001
Function
Supplies power to the DSU/CSU by providing an
attachment for the ac power module or the optional dc
power cable (+24 or –48 Vdc).
Supports SNMP LAN Adapter or daisy-chain connections.
Provides access to a locally connected PC, ASCII terminal
or printer, SNMP management link, or async terminal
interface.
Provides a connection to the integral modem for access to
a remotely connected PC, ASCII terminal or printer, SNMP
management link, or async terminal interface.
Provides access to the T1 network.
Provides access to the DTE Drop/Insert (DSX-1) interface.
Used to attach an external clock to the DSU/CSU.
Used to connect the customer's synchronous data DTE to
the DSU/CSU.