Performance Reports - Paradyne 3163 User Manual

Paradyne acculink dsu/csu user's guide 3163
Hide thumbs Also See for 3163:
Table of Contents

Advertisement

Performance Reports

When the network interface is configured for ESF
operation, network performance is continuously
monitored and maintained in two sets of aggregate
registers: Carrier Network Interface Registers (Telco) and
User Network Interface Registers (User). The User
registers contain an extra status register (Status Event).
Registers shown on the front panel LCD are listed in
Table
4-3. These registers are status registers that collect
performance data for the previous 24-hour period.
Performance data is updated in 15-minute intervals. After
15 minutes, the current interval is rolled over into a set of
accumulator registers that represent the previous 96
15-minute intervals for the register. An interval total of
how many of the 96 registers contain valid data is also
kept, as well as a 24-hour total for each accumulator
register.
"
Procedure
To display User Network Interface (User) performance:
1. From the top-level menu screen, select Stat.
2. From the Status screen, select Perf.
Status:
DevHS STest Perf
F1
3. Select User registers.
Performance:
Telco
F1
4. From the User Registers screen, press F1 to view
current registers (go to Step 5), press F2 to view
24-Hour Totals (go to Step 6), or press F3 to view
15-Minute Interval Registers (go to Step 7).
User Registers:
Cur
F1
3163-A2-GB20-10
F3
F2
User
F2
F3
24Tot
Intvl
F2
F3
5. When you press F1 from the User Registers
screen, the User registers for the current
15-minute interval appear.
6. When you press F2 from the User Registers
screen, the User registers for the 24-hour total
interval appear.
7. When you press F3 from the User Registers
screen, the interval screen appears. Use this screen
to choose the specific 15-minute interval.
8. Use the
under the first or second digit in the interval
number displayed, then use the F1 (Up) and
F2 (Down) keys to increment/ decrement the
number.
9. When you have selected the number of the interval
you want to display, press F3 (Dsply) to display
the registers for the interval selected. Use the
scroll keys to view additional register information.
March 1999
Monitoring and Testing
User Current:
Event = xx,xxx
F1
F2
F3
User 24 Hour:
VldIntvl = xx
F1
F2
F3
User Intvl: 01
Up
Down
Dsply
F3
F1
F2
and
keys to position the cursor
User Intvl: xx
ES= xxx
F1
F2
F3
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acculink 3163 dsuAcculink 3163 csu

Table of Contents