Configuring Bfd For A Pw - HP 6127xlg Configuration Manual

Blade switch series
Hide thumbs Also See for 6127xlg:
Table of Contents

Advertisement

2.
Create the PW, and reference the PW class created in the previous step for the PW.
Perform the following task in any view:
Task
Use MPLS ping to verify the
connectivity of a PW.

Configuring BFD for a PW

Follow these steps to configure BFD for a PW:
1.
Enable BFD for MPLS.
2.
Create a PW class, and configure BFD for PW connectivity verification in PW class view.
3.
Create the PW, and reference the PW class created in the previous step for the PW.
Whether BFD is used to verify PW connectivity, which encapsulation type is used for the BFD packets,
and which CC type is used are determined by the configurations on both ends of the PW.
If both PEs of the PW have configured BFD for the PW and use the same BFD packet encapsulation
type, the PEs use the specified encapsulation type to verify the PW connectivity. Otherwise, the PEs
do not use BFD to verify the PW connectivity.
If both PEs have specified the same VCCV CC type, the specified VCCV CC type is used. Otherwise,
the PEs do not use any CC and they cannot establish a BFD session for the PW.
Configuring BFD for an MPLS L2VPN PW
Perform this task to use BFD to verify the connectivity of a static PW or an LDP PW of MPLS L2VPN:
Step
1.
Enter system view.
2.
Enable BFD for MPLS.
3.
Create a PW class and enter
PW class view.
4.
Use BFD to verify PW
connectivity.
5.
Specify the VCCV CC type.
6.
Return to system view.
7.
Enter cross-connect group
view.
8.
Enter cross-connect view.
Command
ping mpls [ -a source-ip | -c count | -exp exp-value | -h ttl-value | -m
wait-time | -r reply-mode | -rtos tos-value | -s packet-size | -t time-out |
-v ] * pw ip-address pw-id pw-id
Command
system-view
mpls bfd enable
pw-class class-name
vccv bfd [ template
template-name ]
vccv cc router-alert
quit
xconnect-group group-name
connection connection-name
420
Remarks
N/A
By default, BFD for MPLS is
disabled.
By default, no PW class is created.
To use BFD to verify connectivity of a
PW, you must create a PW class for
the PW and configure VCCV
settings in PW class view.
By default, BFD is not used to verify
PW connectivity.
By default, no VCCV CC type is
specified.
N/A
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents