IBM TS7650G User Manual page 30

Deduplication gateway for protectier
Hide thumbs Also See for TS7650G:
Table of Contents

Advertisement

About this task
Perform the following steps to configure the server by using the ProtecTIER
Service menu:
Procedure
1. On the server, if it is not already displayed, access the ProtecTIER Service
2. Select the ProtecTIER Configuration (...) option. Type the corresponding
3. Select the IP Network configuration (...) option. Type the corresponding
4. Select the option Configure ProtecTIER's IP interfaces to configure external.
10
IBM TS7650G Deduplication Gateway for ProtecTIER
menu. See "Accessing the ProtecTIER Service menu" on page 9.
number and press Enter. The ProtecTIER Configuration (...) menu appears.
------------------------------------------------------------------------------
ProtecTIER Service Menu running on rassmx
ProtecTIER Configuration (...)
------------------------------------------------------------------------------
1) Configure ProtecTIER node
2) Recover Configuration for a replaced server
3) Configure machine serial number for a replaced server
4) Configure RAS
5) Update Time, Date, Timezone & Timeserver(s)
6) Scan storage interconnections
7) File systems Management (...)
8) Configure replication (...)
9) IP Network configuration (...)
10) Update Firmware (...)
11) Update the system's name
12) Validate configuration
13) Single Node - code upgrade
14) OS images Management (...)
15) Replace SAS drive
B) Back
E) Exit
------------------------------------------------------------------------------
>>> Your choice?
number and press Enter. The IP Network configuration (...) menu appears.
----------------------------------------------------------------------
ProtecTIER Service Menu running on rasddx
ProtecTIER Configuration (...)
IP Network Configuration (...)
----------------------------------------------------------------------
1) Configure hostname
2) Configure ProtecTIER's IP interfaces
3) Configure Static Routes
4) Configure Baseboard Management Controller (BMC) IP
5) Configure RAS switch
B) Back
E) Exit
----------------------------------------------------------------------
>>> Your choice?
Type the corresponding number and press Enter.
If asked if you would like to stop the vtfd service, type yes and press Enter.
The following status message displays as the system initiates shutdown:
Stopping VTFD [/]
The shutdown process may take a few minutes to complete.
When shutdown completes, the following status message appears:
Stopping RAS [ Done ]
Stopping VTFD [ Done ]
®