10. Type yes and press Enter.
11. Press Enter to return to the ProtecTIER Configuration Menu.
12. Quit the menu to exit. Type q and press Enter. You are returned to the login
13. Configuration for one source server and the destination server, is now
14. To configure additional servers for a many-to-one configuration or
Setting the timezone
Use the procedures in this task to change the time zone setting to match that of
your location. You must set the timezone to ensure accurate system timekeeping.
Procedure
1. On the ProtecTIER Configuration (...) menu (see "Setting the timezone"), select
Target
ID
Network Address
1
10.11.194.0
2
10.11.196.0
Note: The addresses in the above summary are examples. Your actual values
will vary.
The Available Options prompt displays a third time:
Available Options:
==================
(a)dd a new record
(e)dit a record
(d)elete a record
(c)ommit changes
(q)uit
Please Choose (a,e,d,c,q):
9. Type: q <enter>
The Would you like to commit the changes performed to the routing table
now? (yes|no) message, displays.
The Successfully committed changes! message displays.
prompt.
complete. Confirm that your replication configuration was successful. To do
so, refer to the instructions in Chapter 13, "Native replication management (for
FSI)," on page 99.
many-to-many configuration, repeat the steps in "Configuring the application
IP interfaces" on page 11, until each of your remaining servers are configured
and the connections are verified.
the Update Time, Date, Timezone & Timeserver(s) option. Type the
corresponding number for this selection and press Enter.
The Date, Time, Timezone & Timeserver(s) configuration menu, displays:
Chapter 2. Completing the ProtecTIER system setup for new installations
Local Gateway
Target Netmask
Address
255.255.255.0
10.11.195.1
255.255.255.0
10.11.197.1