This section details the safety precautions and inventory check when installing the Harmonic
ProView 2900 Series. It also details the initialization and basic configuration instructions for a
newly installed ProView 2900..
3.1.
Safety Precautions
To avoid injury and prevent equipment damage, observe the following safety precautions:
Do not move or ship equipment unless it is correctly packaged in its original wrapping
•
and shipping containers.
Only Harmonic trained personnel can perform service and maintenance.
•
To prevent lightning damage, ground the unit according to local regulations.
•
Do not permit unqualified personnel to operate the unit.
•
3.1.1. Restricted Access Area
The DC powered equipment should only be installed in a Restricted Access Area.
3.1.2. Installation Codes
This device must be installed according to national electrical codes. For North America,
equipment must be installed in accordance with the US National Electrical Code, Articles 110-
16, 110-17, and 110-18 and the Canadian Electrical Code, Section 12.
Add Markings for AC units for Denmark, Finland, and Sweden (marked on product):
Denmark- "Unit is class I, unit shall be used with an AC cord set suitable with Denmark
•
deviations. Cord shall including an earthing conductor. Unit shall be plugged into a wall
socket outlet which connected to protective earth. Socket outlets which are not connected
to earth shall not be used!"
Finland - (Marking label and in manual) -"Laite on liitettävä suojamaadoituskoskettimilla
•
varustettuun pistorasiaan"
Sweden (Marking label and in manual) - "Apparaten skall anslutas till jordat uttag."
•
For North American
Power connection, select a power supply cord that is UL Listed and CSA Certified 3 -
conductor, [18 AWG], terminated in a molded on plug cap rated 125 V, [15 A], with a
minimum length of 1.5m [six feet] but no longer than 4.5m...For European connection, select
a power supply cord that is internationally harmonized and marked "<HAR>", 3 - conductor,
0,75 mm2 minimum mm2 wire, rated 300 V, with a PVC insulated jacket. The cord must have
a molded on plug cap rated 250 V, 10 A...".
© Harmonic Inc. Manual p/n 101543/Ver 1.0
3-1
ProView 2900 Series/SW Version 1.94
Chapter 3
Installation