K
Quickly attach the emptied drain bottle to the machine once more.
L
Press [ENTER].
EMPTY
DRAIN BOTTLE
WARNING
Never place discharged fluid or ink near an open flame.
Doing so may cause a fire.
CAUTION
To store discharged fluid temporarily, place it in the included drain bottle
or in a durable sealed container such as a metal can or polyethylene tank,
and cap the container tightly.
Any spillage or vapor leakage may cause a fire, an odor, or physical distress.
Dispose of discharged fluid properly, in accordance with the laws in effect in your locale.
Discharged fluid is flammable and contains toxic ingredients. Never attempt to incinerate discharged fluid
or discard it with ordinary trash. Also, do not dispose of it in sewer systems, rivers, or streams. Doing so may
have an adverse impact on the environment.
The screen shown in the following figure appears, and then cleaning starts. The (approximate) re-
maining time for the procedure is displayed on the screen. (The display shown below is an example.
"01:45" = "1 minute and 45 seconds")
CLEANING...
>>
When finished, the screen shown below appears again.
SUPER CL.
AB
M
Press [MENU] to go back to the original screen.
N
Perform a printing test again to make sure the dot drop-out has been corrected.
P. 54 "Step 5 : Printing Tests and Normal Cleaning"
"
When Dot Drop-outs/Uneven Colors Are Not Fixed