Chapter 3 - SmartController Operation

AUTO Boot

When using the SmartController in an AUTO Boot configuration, DIP switch SW1 must
be set to the switch settings shown in row #5 of
AUTO boot.
3.5

SmartController Serial I/O Connectors

The SmartController CS has two serial I/O connectors, an RS-232/Term and an
RS-422/485 port. See
The SmartController CX has two additional serial connectors, RS-232-1 and RS-232-2. See
Figure 3-2 on page 40

RS-232 Connectors

All three of the RS-232 connectors are 9-pin DB9 male (standard PC) connectors. The
user-supplied cable to connect to the RS-232 connectors should be a DB9, F/F,
null-modem data transfer cable. The pin assignments are the same for all three connectors
and are shown in
These ports support the DTR, DCD, RTS, and CTS signals used for hardware handshaking
(also known as modem control). By default, these signals are not enabled. To configure
hardware handshaking and other communication parameters, use the CONFIG_C utility
+
program, the V
designations for these ports when referenced in a V
shown in
Table 3-5 on page
If you are using a customer-supplied ASCII terminal, it plugs the RS-232/Term connector
on the SmartController.
44
Figure 3-1 on page 37
for the connector locations.
Table
3-4.
FSET program instruction, or the FSET monitor command. The V+
45.

Table 3-4. RS-232 Connector Pin Assignments

Pin
Signal
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
NC
7
RTS
8
CTS
9
NC
Adept SmartController User's Guide, Rev. E
and the NVRAM switches set for
Table 3-3
for the connector locations.
+
ATTACH or FSET instruction are
Type
Input
Input
Output
Output
Ground
Output