A.4 Using Multiple sDIO Modules

Additional sDIO modules can be added to a system. The recommended maximum is four
sDIO modules for a SmartController CS system and eight sDIO modules in a CX. See
Figure A-5
for cabling and configuration information. Note that each sDIO must have a
unique block number (between 16 and 31) for both the input and output signals.
1. Connect a 24VDC cable from the XDC2 port on sDIO #1 to the XDC1 port on sDIO
#2. See the
2. Connect an IEEE 1394 cable from one of the IEEE 1394 ports on sDIO #1 to one of
the IEEE 1394 ports on sDIO #2.
3. Execute CONFIG_C and select a block number for sDIO #2. Block 17 is
recommended. See
details on this process.
4. In CONFIG_C, continue to assign groups of signal numbers to bytes 1 to 4 in the
block. See
5. Repeat steps 1 to 4 for each additional sDIO module.
6. Exit CONFIG_C and reboot the controller.
IEEE-1394
1.1
1.2
R
LINK
OK
SF
1394 cable
IEEE-1394
1.1
1.2
R
LINK
OK
SF
1394 cable
IEEE-1394
1.1
1.2
R
LINK
OK
SF
1394 cable
IEEE-1394
1.1
1.2
R
LINK
OK
SF
1394 cable
R
IEEE-1394
OK
HPE
LAN
SW1
1.1
1.2
SF
ES
HD
1 2 3 4
ON
OFF
1
2
3
XDIO
1394 cable
NOTE: When adding additional sDIO modules, each additional sDIO
module must be grounded per all applicable regulations.
102
"Connecting Power" on page 30
"Modifying the Default sDIO Configuration" on page 98
"sDIO Signal Mapping Example 2" on page
Adept sDIO
*S/N 3563-XXXXX*
X1
X2
X3
X4
XDC1 XDC2
24V
0.5A
Module #4
- +
- +
24VDC cable
Adept sDIO
*S/N 3563-XXXXX*
X1
X2
X3
X4
XDC1 XDC2
24V
0.5A
Module #3
- +
- +
24VDC cable
Adept sDIO
*S/N 3563-XXXXX*
X1
X2
X3
X4
XDC1 XDC2
24V
0.5A
Module #2
- +
- +
24VDC cable
Adept sDIO
*S/N 3563-XXXXX*
X1
X2
X3
X4
XDC1 XDC2
24V
0.5A
- +
- +
Module #1
24VDC cable
*S/N 3561-XXXXX*
Adept
Device Net
Eth 10/100
RS-232/TERM
RS-422/485
SmartController
XSYS
XFP
XMCP
XUSR
XDC1 XDC2
24V
5A
- +
- +
24VDC from
Customer-supplied
power supply

Figure A-5. Using Multiple sDIO Modules

Adept SmartController User's Guide, Rev. E
for cabling requirements.
101.
Recommended
Configurations
Block 19
Input Signals 1129 to 1160
Output Signals 0129 to 0160
Block 18
Input Signals 1097 to 1128
Output Signals 0097 to 0128
Block 17
Input Signals 1065 to 1096
Output Signals 0065 to 0096
Block 16 (default)
Input Signals 1033 to 1064
Output Signals 0033 to 0064