24VDC Power Cabling

In order to maintain compliance with EN standards, DC power must be delivered over a
shielded cable, with the shield connected to the return conductors at both ends of the
cable as shown in
Figure
size. The maximum length for the 24VDC cable is 10 meters.
Adept SmartController
-
+
Note: Use connector
supplied by Adept at
this end of cable.

Figure 2-6. User Supplied Power Cable

Daisy-Chaining Power

The SmartController is equipped with two DC power connectors. These connectors allow
the daisy-chaining of power from one controller to another or to a sDIO module. When
daisy-chaining power, the power supply circuit must be limited to the lesser of 8 Amps or
the ampacity of the cabling. This can be done with a circuit breaker or a fuse. The DC
power can be applied to either the XDC1 or XDC2 connector.
CAUTION:
Failure to do this could result in damage to the equipment.

Grounding

The SmartController is equipped with a grounding point. See
recommends connecting a ground wire from the ground point on the controller to earth
ground and that all other interconnected Adept components share the same electrical
ground potential. The ground wire must meet all local regulations. Additional grounding
information for other Adept products are provided in the documentation for those
products.
NOTE: The maximum length for the ground wire for the SmartController
is 3 meters.
Adept SmartController User's Guide, Rev. E
2-6. Conductors should be 1.5 mm
Shield
User-Supplied Shielded
Power Cable
Use only one 24VDC power supply per circuit.
Controller Installation
2
2
- 1.85 mm
(16 to 14 AWG) in
+
-
User-Supplied
Power Supply
24VDC, 5A
2-7. Adept
Figure