Chapter 8: Device Management
172
e. Username Field - Enter the username parameter that will be
used in the URL. For example username=admin, where
username is the username field.
f.
Password Field - Enter the password parameter that will be used
in the URL. For example password=raritan, where password is
the password field.
10. Click OK.
To change the active status of a KVM switch port or URL:
1. Choose Device Settings > Port Configuration. The Port Configuration
page opens.
2. Click the Port Name of the target server you want to rename. The
Port Page opens.
3. Deselect the Active checkbox next to the KVM switch target port or
URL to change its active status.
4. Click OK.

Configuring Rack PDU (Power Strip) Targets

The KX II allows you to connect rack PDUs (power strips) to KX II ports.
KX II rack PDU configuration is done from the KX II Port Configuration
page.
Connecting a Rack PDU
Raritan PX series rack PDUs (power strips) are connected to the
Dominion device using the D2CIM-PWR CIM.
To connect the rack PDU:
1. Connect the male RJ-45 of the D2CIM-PWR to the female RJ-45
connector on the serial port of the rack PDU.
2. Connect the female RJ-45 connector of the D2CIM-PWR to any of
the available female system port connectors on the KX II using a
straight through Cat5 cable.
3. Attach an AC power cord to the target server and an available rack
PDU outlet.
4. Connect the rack PDU to an AC power source.