A.2

Input Power Requirements

TABLE A-2
TABLE A-2
Parameter
Nominal Frequencies
Nominal Voltage Range
Maximum Current AC RMS*
AC Operating Range
Maximum VA Rating
Maximum Power Consumption
Maximum Heat Output
*Maximum input current with accessory connected to accessory outlet is 6 A.
A.3

Environmental Requirements

TABLE A-3
environments.
TABLE A-3
Operating Environment:
Temperature range
Humidity
Altitude range
Vibration
Shock
A-2
SPARCstation 5 Model 110 Service Manual • November 1996
lists the input power requirements for the system unit.
Input Power Requirements and Power Dissipation
lists the environmental requirements for both operating and non-operating
Environmental Requirements
0 ˚C to 40 ˚C (32 ˚F to 104 ˚F) at 20%–70% Relative
Humidity (RH), noncondensing—IEC 68-2-1, 68-2-2
5% to 95% RH, noncondensing—IEC 68-2-2, 68-2-3
0 to 3000 meters (0 to 9840 feet), 10 ˚C to 40 ˚C (50 ˚F to
104˚F)—IEC 68-2-40, 68-2-41
0.25 gravity (g) peak, 5–500 Hz, 3 perpendicular axes—
IEC 68-2-6
5 g peak, 11 milliseconds half-sine pulse—IEC 68-2-27
Specification
50 Hz or 60 Hz nominal
100-120 Vac or 200-240 Vac
(100-240 Vac Auto)
2 A @ 100-120 Vac, 1 A @ 200-240 Vac
87-264 Vrms, 47-63 Hz
200 VA
200 Watts
683 BTU/hr