Configuring Lacp - Lenovo Flex System Fabric CN4093 Application Manual

10gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

Configuring LACP

1. Configure port parameters. All ports that participate in the LACP trunk group 
2. Select the port range and define the admin key. Only ports with the same admin 
3. Set the LACP mode.  
4. Optionally allow member ports to individually participate in normal data traffic if 
5. Set the link aggregation as static, by associating it with trunk ID 65:
144
CN4093 Application Guide for N/OS 8.2
Use the following procedure to configure LACP for ports 7, 8, and 9 to participate 
in a single link aggregation. 
must have the same settings, including VLAN membership. 
key can form an LACP trunk group.  
CN4093(config)# interface port 7­9
CN4093(config­if)# lacp key 100
CN4093(config­if)# lacp mode active
CN4093(config­if)# exit
no LACPDUs are received.
CN4093(config­if)# no lacp suspend­individual
CN4093(config­if)# exit
CN4093(config­if)# portchannel 65 lacp key 100

Advertisement

Table of Contents
loading

Table of Contents