2. Enable the vNIC feature on the switch.
3. Configure the virtual pipes for the vNICs attached to each internal port:
4. Add ports, trunks, and virtual pipes to their vNIC groups.
© Copyright Lenovo 2015
CN4093(config)# vnic enable
CN4093(config)# vnic port INTA1 index 1 (Select vNIC 1 on the port)
CN4093(vnic­config)# enable 
CN4093(vnic­config)# bandwidth 60 
CN4093(vnic­config)# exit
CN4093(config)# vnic port INTA1 index 2(Select vNIC 2 on the port)
CN4093(vnic­config)# enable 
CN4093(vnic­config)# bandwidth 40
CN4093(vnic­config)# exit
CN4093(config)# vnic port INTA2 index 1 (Select vNIC 1 on the port)
CN4093(vnic­config)# enable 
CN4093(vnic­config)# exit
CN4093(config)# vnic port INTA2 index 2 (Select vNIC 2 on the port)
CN4093(vnic­config)# enable 
CN4093(vnic­config)# exit
As a configuration shortcut, vNICs do not have to be explicitly enabled in this step. 
When a vNIC is added to the vNIC group (in the next step), the switch will prompt 
you to confirm automatically enabling the vNIC if it is not yet enabled (shown for 
INT3.2).
Note: vNICs are not supported simultaneously on the same switch ports as
VMready.
CN4093(config)# vnic vnicgroup 1
CN4093(vnic­group­config)# vlan 1000
CN4093(vnic­group­config)# member INTA1.1(Add vNIC pipes to the group)
CN4093(vnic­group­config)# member INTA2.1
CN4093(vnic­group­config)# port INTA4   (Add non‐vNIC port to the group)
CN4093(vnic­group­config)# port EXT1
CN4093(vnic­group­config)# failover
CN4093(vnic­group­config)# enable
CN4093(vnic­group­config)# exit
CN4093(config)# vnic vnicgroup 2
CN4093(vnic­group­config)# vlan 1774
CN4093(vnic­group­config)# member INTA1.2
CN4093(vnic­group­config)# member INTA2.2
CN4093(vnic­group­config)# member INTA3.2
vNIC 3.2 is not enabled.
Confirm enabling vNIC3.2 [y/n]: y
CN4093(vnic­group­config)# port INTA5
CN4093(vnic­group­config)# trunk 1
CN4093(vnic­group­config)# failover
CN4093(vnic­group­config)# enable
CN4093(vnic­group­config)# exit
Once VLAN 1000 and 1774 are configured for vNIC groups, they will not be 
available for regular configuration.
Note: vNICs are not supported simultaneously on the same switch ports as
VMready.
(Enable the vNIC pipe)
(Allow 60% egress bandwidth)
(Enable the vNIC pipe)
(Allow 40% egress bandwidth)
(Enable the vNIC pipe)
(Enable the vNIC pipe)
(Select vNIC group)
(Specify the VLAN)
(Add uplink port to the group
(Enable vNIC failover for the group)
(Enable the vNIC group)