FCoE Mode
Auto-VLAN Mode
© Copyright Lenovo 2015
FCoE traffic is carried by a vPort. The server‐side endpoint of this virtual port will 
be represented through a FC vHBA. Setting a virtual port in FCoE mode will 
enable Priority‐based Flow Control (PFC) on the physical port.
A vPort configured in FCoE mode can only be attached to a Fibre Channel (FC) 
VLAN. Only vPort 2 on a physical port can be configured in FCoE mode. A vPort 
in FCoE mode operates as a local domain data path type with packets being single 
tagged.
When a vPort is configured in auto‐VLAN mode, the vPort participates in VM 
discovery using VMready or 802.1Qbg. VLANs are dynamically provisioned based 
on VMready discovery or 802.1Qbg VM association.
When a vPort operates in auto‐VLAN mode, it supports 32 VM groups. In the case 
of 802.1Qbg, when a vPort operates in auto‐VLAN mode, the maximum number of 
VLANs in the inner tag is 1024 when switch is configured in standalone mode. 
The vPort cannot be configured in Virtual Ethernet Port Aggregator (VEPA) mode.
Chapter 22: Unified Fabric Port