Example 2: Trunk Mode

1. Turn on UFP. 
2. Configure internal port 1 as UFP. 
3. Configure virtual port. 
4. Configure vPort trunk mode. 
5. Configure vPort default VLAN. 
6. Specify QoS parameters for the vPort. 
7. Enable vPort. 
8. Configure internal port 2 as UFP. 
9. Configure virtual port. 
10. Configure vPort trunk mode. 
332
CN4093 Application Guide for N/OS 8.2
Following is an example configuration of UFP vPorts in trunk mode. 
CN4093(config)# ufp enable
CN4093(config)# ufp port INTA1 enable
Warning: "Tagging/Trunk­mode" is enabled on UFP port INTA1
CN4093(config)# ufp port INTA1 vport 1
CN4093(config_ufp_vport)# network mode trunk
CN4093(config_ufp_vport)# network default­vlan 100
CN4093(config_ufp_vport)# qos bandwidth min 25                   (in 
percentage)
CN4093(config_ufp_vport)# qos bandwidth max 100                  (in 
percentage)
CN4093(config_ufp_vport)# enable
CN4093(config_ufp_vport)# exit
CN4093(config)# ufp port INTA2 enable
Warning: "Tagging/Trunk­mode" is enabled on UFP port INTA2
CN4093(config)# ufp port INTA2 vport 3
CN4093(config_ufp_vport)# network mode trunk