Example 2: Trunk Mode
1. Turn on UFP.
2. Configure internal port 1 as UFP.
3. Configure virtual port.
4. Configure vPort trunk mode.
5. Configure vPort default VLAN.
6. Specify QoS parameters for the vPort.
7. Enable vPort.
8. Configure internal port 2 as UFP.
9. Configure virtual port.
10. Configure vPort trunk mode.
332
CN4093 Application Guide for N/OS 8.2
Following is an example configuration of UFP vPorts in trunk mode.
CN4093(config)# ufp enable
CN4093(config)# ufp port INTA1 enable
Warning: "Tagging/Trunkmode" is enabled on UFP port INTA1
CN4093(config)# ufp port INTA1 vport 1
CN4093(config_ufp_vport)# network mode trunk
CN4093(config_ufp_vport)# network defaultvlan 100
CN4093(config_ufp_vport)# qos bandwidth min 25 (in
percentage)
CN4093(config_ufp_vport)# qos bandwidth max 100 (in
percentage)
CN4093(config_ufp_vport)# enable
CN4093(config_ufp_vport)# exit
CN4093(config)# ufp port INTA2 enable
Warning: "Tagging/Trunkmode" is enabled on UFP port INTA2
CN4093(config)# ufp port INTA2 vport 3
CN4093(config_ufp_vport)# network mode trunk