Updating from Lenovo Networking OS 7.7 or Prior

1. Delete the trigger (CN4093(config)# no failover trigger x).
2. Reconfigure the trigger using the appropriate commands. For the UFP‐enabled 
3. Enable the trigger (CN4093(config)# failover trigger x enable).
1. Remove the UFP‐enabled port from the trigger 
2. Add the vPorts as members of the failover trigger 
340
CN4093 Application Guide for N/OS 8.2
CN4093(config)# failover enable
CN4093(config)# failover trigger 1 mmon monitor member EXT1
CN4093(config)# failover trigger 1 mmon control member INTA8
CN4093(config)# failover trigger 1 mmon control vmember 
Note: If you try to add a physical port (that has vPorts configured) as a 
member of a trigger, you may see the following error message when you 
enable the trigger:
CN4093(config)#failover trigger 1 ena
Failover Error: trigger 1 physical port INTA9 has 
virtual ports.
CN4093(config)# failover trigger 1 enable
Beginning with N/OS 7.8, physical ports that have UFP enabled cannot be 
members of a failover trigger; only the vPorts can be members of a failover trigger. 
In a previous configuration (N/OS 7.7 or prior), If you had UFP‐enabled ports as 
members of a failover trigger, the trigger will not work as expected after you 
update the switch software version to N/OS 7.8 or later.You may also experience 
other issues, such as not being able to shutdown or restart the UFP‐enabled ports. 
To overcome this issue, do the following: 
port, add the vPorts as members of the failover trigger 
(CN4093(config)# failover trigger x mmon control vmember 
<vPorts list separated by comma>). See Step 2 on page
OR
(CN4093(config)# no failover trigger x mmon control member 
<UFP‐enabled port number>).
(CN4093(config)# failover trigger x mmon control vmember 
<vPorts list separated by comma>).
INTA9.1,INTA9.2,INTA9.3,INT
A9.4
340 for an example.