Fcoe Requirements - Lenovo Flex System Fabric CN4093 Application Manual

10gb converged scalable switch
Hide thumbs Also See for Flex System Fabric CN4093:
Table of Contents

Advertisement

FCoE Requirements

© Copyright Lenovo 2015
For the FCoE portion of the network, the internal FCF is connected to a blade 
server (running Fibre Channel applications) through an FCoE‐enabled Converged 
Network Adapter (CNA) known in Fibre Channel as an Ethernet Node (ENode).
Note: The figure also shows a non-FCoE LAN server connected to the CN4093
using a CNA. This allows the LAN server to take advantage of some CEE features
that are useful even outside of an FCoE environment.
In order to block undesired or unvalidated traffic on FCoE links that exists outside 
the regular Fibre Channel topology, Ethernet ports used in FCoE are configured 
with Access Control Lists (ACLs) that are narrowly tailored to permit expected 
FCoE traffic to and from confirmed FCFs and ENodes, and deny all other FCoE or 
FIP traffic. This ensures that all FCoE traffic to an from the ENode passes through 
the FCF.
Because manual ACL configuration is an administratively complex task, the 
CN4093 can automatically and dynamically configure the ACLs required for use 
with FCoE. Using FCoE Initialization Protocol (FIP) snooping (see "FCoE 
Initialization Protocol Snooping" on page
frames normally exchanged between the FCF and ENodes to determine 
information about connected FCoE devices. This information is used to 
automatically determine the appropriate ACLs required to block certain types of 
undesired or unvalidated FCoE traffic.
Automatic FCoE‐related ACLs are independent from ACLs used for typical 
Ethernet purposes.
The following are required for implementing FCoE using the Lenovo Flex System 
Fabric CN4093 10Gb Converged Scalable Switch (CN4093) with N/ OS 8.2 
software:
The CN4093 must be connected to the Fibre Channel network using the switch's 
built‐in Fibre Channel features (see "Fibre Channel" on page
FCF device such as another CN4093 switch or a Cisco Nexus 5000 Series Switch.
For each CN4093 internal port participating in FCoE, the connected blade server 
must use the supported FCoE CNA. Emulex Virtual Fabric Adapters (VFAs) for 
Lenovo Flex System, which includes vNIC support, is currently a supported.
For each CN4093 internal port participating in FCoE, the connected blade server 
must include the appropriate FCoE licenses installed, as obtained using the 
Lenovo website Features on Demand (FoD) service. Contact your sales represen‐
tative for more information on obtaining server feature licenses.
CEE must be turned on (see "Turning CEE On or Off" on page
on, the DCBX, PFC, and ETS features are enabled and configured with default 
FCoE settings. These features may be reconfigured, but must remain enabled in 
order for FCoE to function.
FIP snooping must be turned on (see "FCoE Initialization Protocol Snooping" on 
page
268). When FIP snooping is turned on, the feature is enabled on all ports by 
default. The administrator can disable FIP snooping on individual ports that do 
not require FCoE, but FIP snooping must remain enabled on all FCoE ports in 
order for FCoE to function.
268), the CN4093 examines the FIP 
291), or an external 
265). When CEE is 
Chapter 18: FCoE and CEE
263