Rebooting Stacked Switches using the BBI
© Copyright Lenovo 2015
The Configure > System > Config/Image Control window allows the
administrator to perform a reboot of individual switches in the stack, or the entire
stack. The following table describes the stacking Reboot buttons.
Table 20.
Stacking Boot Management buttons
Field
Description
Reboot Stack
Performs a software reboot/reset of all switches in the stack.
The software image specified in the Image To Boot drop‐down
list becomes the active image.
Reboot Master
Performs a software reboot/reset of the Master switch. The
software image specified in the Image To Boot drop‐down list
becomes the active image.
Reboot Switches Performs a reboot/reset on selected switches in the stack. Select
one or more switches in the drop‐down list, and click Reboot
Switches. The software image specified in the Image To Boot
drop‐down list becomes the active image.
The Update Image/Cfg section of the window applies to the Master. When a new
software image or configuration file is loaded, the file first loads onto the Master,
and the Master pushes the file to all other switches in the stack, placing it in the
same software or configuration bank as that on the Master. For example, if the new
image is loaded into image 1 on the Master switch, the Master will push the same
firmware to image 1 on each Member switch.
215
Chapter 14: Stacking