The PBX makes it possible that some functions with the configuration
program COMset are differently configured e.g. for day, night, holiday
and lunch break. Up to a maximum of 6 different configurations are sup-
ported. The following functions are dependent on the configuration:
Exchange line authorizations
External and door call distribution
External call forwarding from door terminal
Connection without dialling (Automatic dialling)
Follow-me
Internal dialling tone
Number presentation
Subscriber-/group-call forwarding
Preferred exchange line
The switching from one configuration to another can be done by time
automation controlled by the internal clock of the PBX or via telephone
(manually)
(page 23 in the user
lowing settings have to be done in COMset for the use of the configura-
tion:
For the system display SD-420 (Auerswald accessory) connected to the
PBX three different operation modes can be selected in COMset:
Operation Mode „Subscriber Display" 1 and 2
Operation Mode „Reception" 3
Operation Mode „Subscriber Display" 1 and 2
In these operation modes the system display is assigned to one sub-
scriber in COMset.
100 --- --- K5 14:59
--- 350 --- }# A:1/2
530 540 550
100 --- --- K5 14:59
--- 350 --- }# A:1/2
530 540 550
Ruf an 390
In the idle mode (Example above) the system display shows the time
14:59
(
) and the busy status. The subscriber gets information about the
active exchange line connections (
lines) and who can not be called at the present moment, e.g. he is cur-
100
rently making a call (
: Subscriber 100 can not be called, ---: Sub-
scriber is available). For this purpose you need to configure with COM-
set the 9 subscribers.
If one or more door terminals are available, a busy door terminal (
Door 2 is busy) and a pressed door bell button (
button 1 is pressed) will be displayed.
Additional informations are displayed: The currently active configuration
K5
(
: Configuration 5 is active). The bell (
active wake-up service configured for the subscriber. The arrow (
signalling an existing entry in the caller list that has not been called
back.
In a status line outgoing (
Ruf an 390
are displayed that have been assigned to the subscriber. Depending of
the configuration in COMset, incoming external calls are displayed with
the caller number (Mode 1) or the called number (one of your external
numbers; Mode 2).

Use different PBX Configurations (Day, Night etc.)

manual). To use configurations the fol-
Configure the System Display SD-420
Example for
COMpact 4410 USB
K:1---
with 2 door terminals
T:-2
K:1---
A:1/2
: 1 of 2 available exchange
K:1---
: door bell
#
) is signalling, that there is an
) and incoming calls or settings
First you have to create the necessary number (up to 6) of configura-
tions. The here listed stated functions can be configured depending on
the configurations.
The time automated switching has to be switched on the switching
times for each day of the week must be entered (up to 10). The activa-
tion of the automatic configuration switching is also possible via tele-
phone
(page 24 in the user
If you want to use manual switching, the authorization has to be
assigned to individual subscribers.
After a power failure the time information is lost. In this case
automatic switching and the Wake-up function will not be per-
formed. After adjusting the time by the programming
sequence on
page 47 in the user manual
the functions will be active again (you can configure in COMset an auto-
matic call to a number e.g. it´s own number for this purpose).
You can switch and monitor the configurations with comfort on a system
telephone. (see manual of the telephone).
By dialling a number preconfigured with COMset you will reach the main
menu of the system display. Pressing the digits displayed in the main
menu you will get into the other menus (e.g. for display of the caller list,
the call charges, wake-up times and configuration switching times). You
can go one level back by pressing the
Please consult the manual of the system display.
Operation Mode „Reception" 3
In this operation mode, the system display is not assigned to a certain
subscriber. Among other things the system display shows the time
15:10
(
) and the busy status. The receptionist gets information on the
active exchange line connections (
lines) and who can not be called at the present moment, e.g. he is cur-
rently making a call (
scriber is available).
If more than 10 subscribers are indicated (in COMset up to 30 or 35
subscribers can be configured without door/switching module, multiple
display of a subscriber is possible) and toggle display is switched on,
the display changes from one page to the other in short intervals.
If one or two door terminals are available, a busy door terminal (
Door 1 is busy) and a pressed door bell button (
ton 3 is pressed) is displayed. The status of the six relays is also dis-
R:1-3---
played (
configuration (
K2
A:1/2
T:1- K:-2-- R:1-3---
125 126 --- --- 129
500 --- --- --- ---
T:-2
:
--- 319 320 --- ---
300 --- 500 --- ---
}
) is
Configuration Options
manual).
or by an outgoing external call
*
key. This is easy to use.
A:1/2
: 1 of 2 available exchange
125
: Subscriber 125 can not be called, ---: Sub-
: Relay 1 and 3 are switched on). The currently active
: Configuration 2 is active) is also displayed.
K2 15:10
43
T:1-
:
K:-2--
: door bell but-
Example for
COMpact 4410 USB
with 2 door terminals

Hide quick links: