Commissioning (COMpact 5000)
• Wait at least 3 minutes for the discharge of any capacitor in the device after disconnecting
it from the main power supply.
• Only operate the device when the casing is closed.
• Only operate the device mounted on the wall.
• Do not remove the covers of the power supply unit and the mainboard. They are a
protection against accidental contact with hazardous voltages and guide the modules.
Make sure that any repairs requiring the casing cover to be removed are carried out by
the manufacturer.
Warning: Power surges, which may occur during electrical storms, can cause life-
threatening electric shocks, or damage or destroy the PBX.
• Do not touch the PBX or any devices connected to it during an electrical storm.
1.
Unlatch
both
compressing each with thumb and index
finger.
2.
Lift the cover and remove it completely from
the casing.

Wall-Mounting the PBX

Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks.
• Mount the PBX close of an earth wire (potential compensation bar of the house installation
or protective earth conductor). Connect the PBX's earth connection to the earth wire with
a connecting cable whose conductor diameter is at least 2.5 mm
Warning: Liquid entering the casing can cause life-threatening electric shocks or
damage or destroy the PBX.
• Only operate the PBX in closed, dry rooms.
Caution: Overheating can damage or destroy the system.
• Note the ambient temperature values indicated in the technical data.
• Make sure that heat produced by the device can be adequately vented into the
environment. Do not install the system in a cabinet without adequate air circulation.
• Never cover the air vents of the casing.
Important: Mechanical loads and electro-magnetic fields can impair PBX operation.
• Avoid mechanical loads (e. g. vibrations).
• Avoid the proximity of devices that generate electro-magnetic fields (e. g., radio sets,
professional radio equipment, amateur radio equipment, mobile phones, DECT systems,
WLAN routers, etc.).