RRP 37 Waste Auger Assembly
Figure 7-39 Waste Auger Assembly
Removal
1.
Remove the Right Side Cover (RRP 2, on page 7-141).
1.
Remove Waste Toner Cartridge and lower the main lever.
2.
Remove Accumulator Belt assembly.
3.
Return the main lever to its upright position.
4.
Remove the two screws securing the Waste Auger Assembly.
5.
Shift the Waste Auger Assembly to remove the drive shaft from the bearing
and remove the waste auger assembly.
Note
Be careful not to knock the bearing out of its seat.
Caution
When reinstalling, be sure to return the main lever down before
reinstalling the Accumulator Belt Assembly.
Service Quick Reference Guide - Removal & Replacement Procedures
S7700-438
7-183