Chapter 2
2) Remove the tape [1], and detach the hopper supply mouth cover [2].
3) Take out the developing assembly from the packing box.
4) Rotate the developing cylinder gear [1] with hand and check if there are
any cuts on the cylinder [2].
[1]
5) Hold the center (grip of the assembly) of the developing assembly [1] and
install it.
Then, connect the connector [2].
Then, connect the connector [2].
When mounting the developing assembly, be sure not to contact the
developing cylinder with the developing assembly mounting plate.
2-10
[2]
[1]
F-2-29
[1]
[2]
F-2-30
[2]
F-2-31
[1]
[2]
6) Fit the developing assembly pressure unit [1] to [2], and slide it in hori-
zontally in the [A] direction; then, shift toward the [B] direction.
- 1 screw (binding; M4X6) [3]
[B]
[A]
[3]

2.2.7 Installation of Pickup Assembly

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
1) Remove the pickup roller pressure release spacer [1].
Remove the pickup roller pressure release spacer [1] while moving the front
side of it upward after sliding the spacer toward the right.
[1]
F-2-32
[2]
[1]
F-2-33