Take-up roller
2) After fitting the fixing web, move the plunger [1] of the web guide sole-
noid in the direction of the arrow until the fixing web is free of the slack.

9.5.11.5 After Replacing the Fixing Web

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
After replacing the fixing web, be sure to reset the counter reading to '0' by
using the following service mode items.
COPIER> COUNTER> MISC> FIX-WEB
COPIER> COUNTER> DRBL-1> FX-WEB

9.5.12 Fixing Jam Sensor

9.5.12.1 Before Removing the Delivery Jam Sensor

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
1) Detach the duplexing feed front cover. (page 10-14)Reference[Remov-
ing the Duplexing Feed Front Cover]
2) Detach the fixing/feeding unit. (page 9-19)Reference[Removing the
Fixing/Feeding unit]
3) Remove the external delivery roller. (page 9-25)Reference[Removing
the External Delivery Roller]

9.5.12.2 Removing the Delivery Jam Sensor

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
1) Slide out the sensor support plate.
- 2 screws [1]
2) Remove the delivery jam sensor [2] from the sensor support plate.
- 1 connector [1]
Feed roller
F-9-102
[1]
F-9-103
[1]
[2]
F-9-104

9.5.13 Claw Jam Sensor

9.5.13.1 Before Removing the Claw Jam Sensor

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
1) Detach the duplexing feed front cover. (page 10-14)Reference[Remov-
ing the Duplexing Feed Front Cover]
2) Slide out the fixing/feeding unit. (page 9-19)Reference[Removing the
Fixing/Feeding unit]
3) Detach the fixing front cover. (page 10-16)Reference[Removing the
Fixing Front Cover]
4) Detach the fixing/feeding unit front cover. (page 10-15)Reference[Re-
moving the Fixing/Feeding Unit Front Cover]
5) Detach the fixing/feeding unit middle cover. (page
ence[Removing the Fixing/Feeding Unit Middle Cover]
6) Detach the fixing upper cover. (page 10-15)Reference[Removing the
Fixing Upper Cover]
7) Remove the fixing drive assembly. (page 10-22)Reference[Removing
0015-9981
the Fixing Drive Assembly]
8) Remove the fixing upper unit. (page 9-20)Reference[Removing the Fix-
ing Upper Unit]
9) Remove the lower separation claw unit. (page 9-39)Reference[Remov-
ing the Lower Separation Claw (Unit)]
10) Remove the internal delivery roller. (page 9-26)Reference[Removing
the Internal Delivery Roller]

9.5.13.2 Removing the Claw Jam Sensor

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
0015-7176
1) Remove the protrusion [2] to slide out the sensor support plate [3].
- 1 screw [1]
0015-5064
2) Remove the claw jam sensor [2] from the sensor support plate.
- 1 connector [1
[2]
[1]
F-9-105
[1]
[3]
[2]
F-9-106
[2]
[1]
F-9-107
Chapter 9
0015-7195
10-15)Refer-
0015-5065
9-33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir5075 seriesIr5065 seriesIr5065Ir5075nIr5065nIr5055 ... Show all

Table of Contents