[1]
[1]
[1]
In the next steps, draw mark-off lines before removing the screw.
16) Remove the 2 cable fixing screws [2] of the No. 1 mirror base [1].
17) Remove the cable fixing spring [3].
18) Free the 2 hooks [4] of the cable from the right side of the reader unit
frame.
19) Detach the cable for the pulleys.
[2]
[3]

5.4.13.4 Fitting the Scanner Drive Cable

iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
1) Put the ball of the cable into the hole of the drive pulley [1], and wind the
cable (4 times inside; 5 times outside); then, tape it in place. At this time,
make sure that the cable fixing [2] is on the inside.
2) Fit the cable on the pulleys; then, fit one end on the left side hook [3] and
the other end on the right side hook [4].
3) Temporarily fix the cable fixing plate [2] in place on the No. 1 mirror base
[5].
4) Mount the reader unit upper frame.
5-28
[1]
[1]
[1]
[2]
F-5-99
[1]
[4]
[4]
[2]
F-5-100
[3]
[3]
5.4.13.5 Adjusting the Position of the No. 1/No. 2 Mirror
Base
0015-4860
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
1) Arrange the mirror positioning tool (FY9-3009-040) so that it is ready for
use in the machine (by changing the pin position; REAR).
[1]
[2]
[1]
[4]
[5]
[2]
F-5-101
[4]
[5]
F-5-102
[4]
[4]
0015-9945