Canon iR5055 Series Service Manual page 565

Hide thumbs Also See for iR5055 Series:
Table of Contents

Advertisement

Sub-item
Description
ERR
Use it to reset an error code.
(codes: E000, E001, E002, E003, E004, E005)
Procedure
1) Select the item, and press the OK key.
2) Turn off and then on the main power.
DC-CON
Use it to initialize the RAM on the DC controller PCB.
The RAM will be initialized when the main power switch is turned off and then back on.
Procedure
1) Print out the service mode particulars using the following: COPIER>FUNCTION>MISC-P>P-PRINT.
2) Select the item, and press the OK key.
3) Turn off and then on the main power switch.
4) As necessary, enter the data you have printed using P-PRINT.
R-CON
Use it to initialize the RAM on the reader controller PCB.
The settings will be initialized when you turn off and then on the main power switch.
Procedure
1) Print out the service mode particulars using the following: COPIER>FUNCTION>MISC-P>P-PRINT.
2) Select the item, and press the OK key.
3) Turn off and then back on the main power.
4) As necessary, enter the data you have printed using P-PRINT.
JAM-HIST
Use it to reset the jam history.
The jam history will be reset when the OK key is pressed.
Procedure
1) Select the item, and press the OK key.
ERR-HIST
Use it to reset the error code history.
The error code will be reset when the OK key is pressed.
1) Select the item, and press the OK key.
PWD-CLR
Use it to reset the password of the system administrator.
The password of 'system administrator' set in user mode is reset when the OK key is pressed.
Procedure
1) Select the item, and press the OK key.
ADRS-BK
Clearing the address book.
The address book is cleared when the main power switch is turned OFF and ON.
CNT-MCON
Use it to reset the service counter whose reading is kept by the main controller PCB.
The counter reading is reset when the OK key is pressed.
Procedure
1) Select the item, and press the OK key.
CNT-DCON
Use it to reset the service counter whose reading is kept by the DC controller PCB.
The counter reading will be reset when the OK key is pressed.
Procedure
1) Select the item, and press the OK key.
OPTION
Use it to reset the service mode setting OPTION to its default setting (as upon RAM initialization).
The setting will be initialized when the OK key is pressed.
The execution of this item will reset the data kept by the main controller, DC controller, and reader controller.
Procedure
1) Print out the service mode particulars using the following: COPIER>FUTON>MISC-P>P-PRINT.
2) Select the item, and press the OK key.
MMI
Use it to reset the following settings of user mode:
- backup user data for copier control panel (user settings)
- common settings backup data (user settings)
- various backup data except FAX data (sure settings)
The settings will be initialized when the main power switch is turned off and then back on.
Procedure
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.
MN-CON
Use it reset the RAM on the main controller PCB.
The RAM will be reset when the main power switch is turned off and then back on.
Procedure
1) Print out the service mode particulars using the following: COPIER>FUNCTION>MISC-P>P-PRINT.
2) Select the item, and press the OK key.
3) Turn off and then back on the main power.
4) As necessary, enter the data you have printed out using P-PRINT.
CARD
Use it to reset the data related to card ID (group).
The card ID-related data will be reset when the main power switch is turned off and then back on.
Procedure
1) Select the item, and press the OK key.
2) Turn off and then back on the main power.
T-17-45
COPIER > FUNCTION > CLEAR
Chapter 17
Level
1
1
1
1
1
1
1
1
1
1
1
1
1
17-33