Code
Description
E612
error in postponement
E674
There is a fault in the communication between the fax controller PCB (2-line) and the main controller PCB.
E710
there is a printer IPC error
E711
there is a printer IPC error
E713
there is a sorter IPC error
E717
the communication with the NE controller is faulty
E719
the coin vendor is faulty
E730
the PDL software is faulty
E732
there is a reader communication error
E733
the printer communication is faulty
E740
the Ethernet board is faulty
E744
the language file/boot ROM is faulty
E746
the accessories board type is wrong
E748
the controller board do not match
E804
there is a DC power supply fan error/there is an IH power supply cooling fan error
E805
there is a heat discharge fan error/there is a feed fan error
E808
there is a IH power supply input error
E821
the cleaner is clogged
E824
there is a primary charging cooling fan error
E840
there is a shutter error
E841
there is an error in the detection of fixing inlet guide solenoid connection

16.2 Error Code Details

16.2.1 Detail Error Code
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
Code
Description
E000
The heater fails to heat.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0000 After power-on, the reading of the main thermistor does not increase to 70
deg C or higher within 20 sec.
0010 The power has been turned off and then on without resetting the error.
E001
There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
0001 There is an error or an open circuit in the main thermistor, shutter
thermistor, or sub thermistor.
0002 The reading of the main thermistor, shutter thermistor, or sub thermistor is
230 deg C or higher for 2 sec.
0003 The reading is not 150 deg C or higher or 210 deg C or lower within 30 sec. -Cheak the connecting of the main/ sub/ shutter thermistors.
0010 The power has been turned off and then back on without resetting the error. - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
E002
There is an abnormal rise in temperature.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
16-2
T-16-2
Remedy
- Replace the main/shutter thermistor.
- Replace the DC controller PCB.
- Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
- Check the connector of each thermistor for any fault in connection and
wiring.
- Replace the thermistor in question.
- Replace the DC controller PCB.
- Replace the thermistor in question.
- Replace the DC controller PCB.
-Check the mounting of the main/ sub/ shutter thermistors.
-Exchange the main/ sub/ shutter thermistors.
-Exchange the DC controller PCB.