Usb Interfaces; Vga Interface; Post Code Sequence; Post Code Example - Kontron CP6005-SA User Manual

6u compactpci processor board
Table of Contents

Advertisement

How to Read the 8-Bit POST Code
Due to the fact that only 4 LEDs are available and 8 bits must be displayed, the POST code output is
multiplexed on the General Purpose LEDs.
Table 10: POST Code Sequence
STATE
0
All LEDs are OFF; start of POST sequence
1
High nibble
2
Low nibble; state 2 is followed by state 0
The following is an example of the General Purpose LEDs' operation if the POST configuration is en-
abled (see also Tables 8 and 9).
Table 11: POST Code Example
LED3
HIGH NIBBLE
of f (0)
LOW NIBBLE
of f (0)
POST CODE
0x41
Note:
Under normal operating conditions, the General Purpose LEDs should not remain lit during
boot-up. They are intended to be used only for debugging purposes. In the event that a
General Purpose LED lights up during boot-up and the CP6005(X)-SA does not boot, please
contact Kontron for further assistance.
2.7.2 USB Inter faces
The CP6005(X)-SA provides six USB 2.0 ports:
»
Two on front I/O
»
Four on the CompactPCI rear I/O interface
On the front panel, the CP6005(X)-SA has two standard, type A, USB 2.0 connectors, J6 and J7.
2.7.3 VGA Inter face
The CP6005(X)-SA provides one standard VGA interface for connection to a monitor. The VGA interface
is implemented as a standard VGA connector, J9, on the front panel.
www.kontron.com
GENERAL PURPOSE LEDs
LED2
LED1
on (1)
of f (0)
of f (0)
of f (0)
LED0
RESULT
of f (0)
0x4
on (1)
0x1
User Guide
CP6005(X)-SA
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp6005x-sa

Table of Contents