Adjusting the faders (Calibration function)

Depending on the environment in which you use the CL series console, discrepancies may occur in the
motion of the motor faders. You can use the Calibration function to correct these discrepancies.
NOTE
For information about adjusting the input gain or the detection point of the touch screen, refer to
the appropriate sections in this chapter.
1.
While holding down the SCENE MEMORY [STORE] key on the panel, turn on the
power to the CL unit.
After the opening screen, the following startup menu screen will appear.
2.
Press the FADER CALIBRATION button.
The FADER CALIBRATION MODE screen will appear, enabling you to adjust the faders.
The specified faders in the channel strip section, Centralogic section, and Master section will be
semi-automatically calibrated. This window will also appear if a problem is detected in the fader
settings while the CL is starting up.
3.
Press a [SEL] key to specify the faders that you want to calibrate.
Faders for which a problem was detected at start-up will already be selected.
4.
Press the START button.
A confirmation dialog box will appear.
5.
Press the OK button in the dialog box.
6.
Each of the specified faders will move to the target positions in the following
sequence. Manually adjust the faders to the correct positions.
1
–∞ (all the way down)
2
–20 dB
3
0 dB
4
+10 dB (all the way up)
7.
After you adjust the fader position, press the [NEXT] button.
The process will proceed to the next fader position.
8.
Repeat steps 6–7 to adjust the faders for positions
After the positions are corrected, automatic motorized calibration will start.
9.
When calibration is complete and if the RESTART button has not appeared, press
the APPLY button.
The calibration settings will be saved in internal memory. If the RESTART button appears,
calibration has failed. Press the RESTART button to execute calibration once again.
10.
Press the EXIT button.
The CL unit will start up in normal operating mode.
NOTE
Alternatively, you can continue operation by selecting a different menu instead of pressing the
EXIT button.