Adjusting The Faders (Calibration Function) - Yamaha CL3 Owner's Manual

Digital mixing console
Hide thumbs Also See for CL3:
Table of Contents

Advertisement

Other functions
Adjusting the faders
(Calibration function)
Depending on the environment in which you use the CL
series, discrepancies may occur in the motion of the motor
faders. You can use the Calibration function to correct
these discrepancies.
NOTE
For information about adjusting the input gain or the
detection point of the touch screen, refer to the Reference
Manual.
1.
While holding down the SCENE MEMORY
[STORE] key on the panel, turn on the power
to the CL unit.
After the opening screen, the following startup menu
screen will appear.
2.
Press the FADER CALIBRATION button.
The FADER CALIBRATION MODE screen will
appear, enabling you to adjust the faders.
The specified INPUT faders, Centralogic faders,
STEREO/MONO faders will be semi-automatically
calibrated. This window will also appear if a problem
is detected in the fader settings while the CL is starting
up.
3.
Press a [SEL] key to specify the faders that you
want to calibrate.
Faders for which a problem was detected at start-up
will already be selected.
4.
Press the START button.
A confirmation dialog box will appear.
5.
Press the OK button in the dialog box.
6.
Each of the specified faders will move to the
target positions in the following sequence.
Manually move the faders to the correct
positions.
1
–∞ (all the way down)
2
–20dB
3
0dB
4
+10dB (all the way up)
52
Owner's Manual
7.
After you adjust the fader position, press the
[NEXT] button.
The process will proceed to the next fader position.
8.
Repeat steps 6–7 to adjust the faders for
positions (1) through (4).
After the positions are corrected, automatic
motorized calibration will start.
9.
When calibration is complete and the
RESTART button has not appeared, press the
APPLY button.
The calibration settings will be saved in internal
memory. If the RESTART button appears, calibration
has failed. Press the RESTART button to execute
calibration once again.
10.
Press the EXIT button.
The CL unit will start up in normal operating mode.
NOTE
Alternatively, you can continue the operation by selecting a
different menu instead of pressing the EXIT button.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl5Cl1

Table of Contents