3.
Use the buttons in the CUE MODE section to specify what will happen when
multiple [CUE] keys within the same CUE group are turned on.
Select the MIX CUE button or LAST CUE button.
NOTE
[CUE] keys belonging to different CUE groups cannot be turned on simultaneously. The CUE
group to which the last-pressed [CUE] key belongs will be turned on, allowing only the signals of
that group to be monitored.
4.
Use the buttons and knobs of the INPUT field, DCA field, and OUTPUT CUE field to
specify the output position and output level for each CUE group.
Refer to the explanation for each item in step 2, and make the desired settings.
5.
To specify a port as the output destination for cue signals L and R, press one of the
CUE OUTPUT buttons (L/R) in the meter field to open the PORT SELECT popup
window, and choose from the following monitor signal output destinations
(multiple selections are allowed).
DANTE 1-64
Output channels 1–64 to audio network
OMNI1–8
OMNI OUT jacks 1–8
DIGI OUT L/R
DIGITAL OUT jack on the CL unit
SLOT1–1 – SLOT3–16
Output channels 1–16 of an I/O card installed in slots 1–3
When you have selected an output port, press the CLOSE button to close the popup window.
6.
Press the [CUE] key for a desired channel or DCA group to turn it on.
The cue signal of the corresponding channel will be sent to the output destination specified in step
5.
The background of the cue meter in the Function Access Area will turn blue, indicating the cue
output level.
An abbreviation for the CUE group or CUE button that is currently turned on appears above the
cue meters.
The abbreviations displayed for the cue meters have the following meaning.
IN
INPUT CUE group
DCA
DCA CUE group
OUT
OUTPUT CUE group
CUE button in the EFFECT and PREMIUM RACK popup windows
EFFECT
(Other CUE groups)
KEY IN CUE button in the DYNAMICS 1 popup window
KEY IN
(Other CUE groups)
CUE meter
NOTE
• When using the MIX/MATRIX bus select buttons in the SENDS ON FADER popup window, you
can press the selected button once again to turn on Cue for the corresponding MIX/MATRIX
channel (see
page
43).
• If you want cue operations and channel select operations to be linked, open the USER SETUP
popup window, choose the PREFERENCE tab, and then turn on "[CUE] → [SEL] LINK"
(see
page
163).
7.
To adjust the cue signal level, use the MONITOR LEVEL knob located in the SCENE
MEMORY/MONITOR section on the top panel.
If PHONES LEVEL LINK is ON, you can use both the MONITOR LEVEL knob and the PHONES
LEVEL knob to adjust the cue signal level when monitoring through headphones.
8.
To defeat cue, press the currently-on [CUE] key once again.
You can press the CLEAR CUE button in the Meter field of the CUE popup window to clear all
cue selections.
NOTE
• If you press the CUE meter in the Function Access Area, all cue selections will be cleared.
• All cue selections will be cleared if you switch between MIX CUE mode and LAST CUE mode in
the CUE MODE section.
• You can also assign the function of the CLEAR CUE button to a USER DEFINED key
(see
page
164).