DYNAMICS 1/2 popup window (CH1-48, CH49-72/ST IN(CL5),
CH49-64/ST IN(CL3), ST IN(CL1), OUTPUT)
This window enables you to make settings of the global dynamics parameters for the corresponding
channel.
1
6
7
8
1
LIBRARY button
2
DEFAULT button
3
COPY button
4
PASTE button
5
COMPARE button
These buttons are the same as those in the DYNAMICS 1ch popup window.
6
Channel select button
Selects the channel that you want to control. The current channel icon, number, threshold, and
color appear on the button.
7
Dynamics parameter area
This area displays the dynamics type and various meters. Press the area to access the DYNAMICS
1ch popup window of that channel.
If DUCKING, EXPANDER, COMPANDER (-H/-S), or DE-ESSER has been selected as the
dynamics type, the type appears near the top of this area.
The lower part of this area displays meters that indicate the levels of signals after dynamics
processing, the GR meter, and the threshold (a numeric value). If the dynamics processor is any
type other than GATE, the threshold setting is indicated as a vertical line.
8
Tabs
Use these tabs to select a channel that you want to view on the screen.
2
3 4
5
3.
Access the DYNAMICS 1/2 popup window (1 ch), and press the DYNAMICS ON
button to enable the dynamics processor.
4.
To select a key-in signal, proceed as follows.
4-1. In the DYNAMICS 1/2 popup window (1 ch), press the KEY IN SOURCE button to
access the KEY IN SOURCE SELECT popup window.
KEY IN SOURCE SELECT pop-up window
4-2. Select the key-in signal. You can choose one of the following signals.
• SELF PRE EQ ............................. The pre-EQ signal of the same channel
• SELF POST EQ .......................... The post-EQ signal of the same channel
• MIX OUT 21–24 ....................... Output signals of MIX channels 21–24
• CH1–72 POST EQ, ST IN1L–8R POST EQ, MIX1–24 POST EQ,
MTRX1–8 POST EQ, ST L/R, MONO POST EQ
........................... The post-EQ signal of the corresponding channel
*1. The selectable signals are limited to the corresponding eight-channel group.
NOTE
In the case of the CL3/CL1, channels that do not exist on those models will not be shown.
4-3. Press the CLOSE button to close the popup window.
5.
If you want to copy dynamics settings to another channel, or initialize the
dynamics settings, use the tool buttons in the popup window.
NOTE
• Dynamics settings can be saved and recalled at any time using the dedicated library. You can
also take advantage of a wide variety of presets suitable for various instruments or situations.
• You can also access the SELECTED CHANNEL VIEW screen, and use the knobs in the
SELECTED CHANNEL section to edit the dynamics settings (see
• Even when the DYNAMICS 1/2 popup window is displayed, you can use the knobs in the
SELECTED CHANNEL section to control the dynamics.
61
EQ and Dynamics
*1
page
9).
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl3Cl1

Table of Contents