Word Clock And Slot Settings - Yamaha CL5 Reference Manual

Dgital mixing console yamaha cl5; cl3; cl1
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

Word clock and slot settings

"Word clock" refers to the clock that provides the basis of timing for digital audio signal processing. To
send and receive digital audio signals between devices, those devices must be synchronized to the same
word clock. If digital audio signals are transferred in an unsynchronized state, the data may not be
transmitted or received correctly, and noise may be present in the signal, even if the sampling rates are
the same.
Specifically, you must first decide which device will transmit the reference word clock for the entire
system (the word clock master), and then set the remaining devices (the word clock slaves) so that they
synchronize to the word clock master.
If you wish to use the CL series console as a word clock slave that is synchronized to the word clock
supplied from an external device, you must specify the appropriate clock source (the port through
which the word clock is obtained).
This section explains how to select the clock source that the CL series console will use.
1.
In the Function Access Area, press the SETUP button to access the SETUP screen.
2.
In the SYSTEM SETUP field at the center of the screen, press the WORD CLOCK/
SLOT SETUP button to open the WORD CLOCK/SLOT SETUP popup window.
This popup window contains the following items.
1
2
■ MASTER CLOCK SELECT field
1
Master clock frequency display
Indicates the frequency (44.1 kHz or 48 kHz) of the currently-selected master clock. If the unit is
not synching to the master clock, "UNLOCK" will appear.
NOTE
If sample rate pull-up/down has been specified in the Dante
Controller application, this area indicates the change in the
sample rate as a percentage, such as –4.0%, –0.1%, +4.0%,
4.1667%, etc.
2
Master clock select buttons
Use the buttons to select the clock source that you want to use as the word clock master from the
following options:
• INT 48 k
• INT 44.1 k
The CL console internal clock (sampling rate 48 kHz or 44.1 kHz) will be the clock source.
• WORD CLOCK IN
The word clock supplied from the WORD CLOCK IN jack on the rear panel of the console will
be used as the clock source.
• DANTE 48 k
• DANTE 44.1 k
The word clock supplied from the Dante jack on the rear panel of the console will be used as the
clock source.