■ RACK ID ASSIGN field
Specifies which multiple I/O racks and Dante-enabled devices will be used.
For example, you can change the assignments between RACK ID and UNIT ID, select desired I/O racks
from nine or more I/O racks, and change the I/O rack type to edit off-line.
5
RACK NO. list
Selects the RACK ID.
6
UNIT ID list
Selects the device UNIT ID that will be assigned to the RACK ID selected in the RACK NO. list.
7
DEVICE TYPE list
Specifies the type of device selected in the UNIT ID list.
If you select a DEVICE TYPE that is listed as (w/RECALL), the data stored in the CL series
console will be reflected in the I/O rack when you restart the CL series console and when you
perform a scene recall.
NOTE
• In cases where an I/O rack is being shared between multiple CL series consoles, and that I/O
rack was set to (w/RECALL) from one CL series console, you must not specify (w/RECALL) from
another CL series console for that I/O rack.
• The settings that are shared in common with the I/O racks (BIT/LATENCY/W.CLOCK) will reflect
the settings of the CL series console whose CONSOLE ID is set to #1.
• The HA etc. of the I/O rack can also be operated from a CL series console that is not set to (w/
RECALL).
8
MOUNT/UNMOUNT button
Mounts/unmounts the I/O rack unit that communicates with the CL series console. Select the
RACK NO that you want to mount; then select the UNIT ID and DEVICE TYPE and press the
MOUNT button to mount the I/O rack. A maximum of eight units with a UNIT ID can be
mounted on one CL series console.
NOTE
If there are I/O rack units or Dante devices in addition to the eight units you've specified and
mounted, they will be automatically mounted in RACK NO #9 through #24.
DVS will be mounted in #9 or later.
9
REFRESH button
Updates the list of devices in the Dante audio network to the latest information.
If a device (that was previously set up) does not exist on the current Dante audio network, a yellow
"Virtual" indicator will appear to the right, below the corresponding device name in the RACK ID list.
If devices on the network belong to different DEVICE TYPEs but share the same UNIT ID, a red
"Conflict" indicator will appear to the right, below the corresponding device names in the RACK ID
list.
If multiple devices share the same UNIT ID, a yellow "Duplicate" indicator will appear to the right,
below the corresponding device names in the RACK ID list.
Operation when editing the DANTE SETUP
• When the DANTE SETUP is edited, the ACCESS indicator will light until the edited settings have
been applied to the console.
Editing the following items will cause the ACCESS indicator to light.
• Parameters in the DANTE SETUP screen
• Parameters in the WORD CLOCK screen
• Changes to DANTE INPUT PATCH, Library operations, and Auto Setup button operations
• Parameters in the OUTPUT tab of the I/O RACK screen
You will need to power-cycle the console in order for changes in DANTE SETUP to take effect,
but you must wait for the ACCESS indicator to go dark before you turn off the power.
• You will need to power-cycle the console after changing the SECONDARY PORT settings in the
DANTE SETUP screen, or after changing the ID of the CL series console or an I/O rack. Proceed as
follows.
Changing the SECONDARY PORT setting
1.
Disconnect the Ethernet cables from the DANTE connector of the CL series console
and the I/O racks.
NOTE
If you're changing the SECONDARY PORT setting, you must also change the method of
connection between the CL series console and the I/O racks. For example if the connections
used for the REDUNDANT setting are left as they are when you change the setting to DAISY
CHAIN, it will become impossible to send and receive audio. Be sure to disconnect the cables
before you change the setting.
2.
Check the REDUNDANT setting of the CL series console and the DIP switch settings
of the I/O rack.
3.
Power-cycle the CL series console and the I/O rack units.
4.
After waiting for approximately one minute, first connect the Ethernet cable to the
DANTE connector of the I/O rack; then after waiting for approximately 20 seconds,
connect the Ethernet cable to the DANTE connector of the CL series console.