4.
If you turned on the MIX ON, MIX SEND, MATRIX ON, or MATRIX SEND buttons in
step 3, use the buttons in the SEND PARAMETERS field to specify the bus(es) for
which you want operations to be linked (multiple selections are allowed).
The table below lists the buttons you can select in the SEND PARAMETERS field.
MIX 1–24
MIX buses 1–24
MATRIX 1–8
MATRIX buses 1–8
NOTE
If nothing is selected in the SEND PARAMETERS field, the send on/off and send level
parameters will not be linked.
5.
To link channels, hold down the [SEL] key for the link-source input channel and
press the [SEL] key for the link-destination channel.
At this time, the values of the parameters you selected in steps 3 and 4 will be copied from the
link-source to the link-destination channel. Subsequent operations of the parameters you selected
in steps 3 and 4 will be linked between channels that belong to the same link group.
The current link status is displayed in the channel display field of the window.
NOTE
• If you want to link three or more channels, hold down the link-source [SEL] key and successively
press the [SEL] key for each channel you want to add to the link group.
• When you press the [SEL] key for a channel (that belongs to a link group) to make it light, the
[SEL] keys of all channels that belong to the same link group will blink.
• If you link an input channel to a ST IN channel, parameters that do not exist for a ST IN channel
will be ignored.
6.
If you want to add a new channel to an existing link group, hold down any [SEL]
key within the group and press the [SEL] key for the channel that you want to add
to the group.
NOTE
If the link-destination channel is already assigned to another link group, the channel will be
removed from the previous group and added to the newly assigned group.
7.
To remove a channel from a link group, hold down any [SEL] key in the same link
group, and press the [SEL] key for the channel that you want to remove.
NOTE
You can also remove all linked channels from the same link group temporarily. This can be helpful
if you want to edit parameters that are linked to each other while maintaining the same relative
level differences. For example, this may be the case for parameters such as the HA analog gain
and fader, or if you want to change the level balance between channels that belong to the same
link group. While pressing and holding down the [SEL] key for the desired linked channel, adjust
the parameter value.
While you are holding down the [SEL] key, the HA analog gain and fader values will not be linked.
(However, you cannot temporarily cancel this link during the "fading" phase of a recalled scene.)
You can also perform the operations from step 5 on screen.
5.
To link channels, press the channel display field.
The CH LINK SET popup window will appear.
6.
Select a channel that you want to link.
7.
To confirm the link, press the LINK
button in the lower left of the screen.
An alphabetical character that indicates the link
group will appear on the selected channel
button.
NOTE
If you use CL5 settings data on the CL3/CL1, or CL3 settings data on the CL1, buttons will be
shown crossed-out if they are assigned to a channel that does not exist on that model.
8.
In the same way, link other channels as you wish.
9.