System-Wide Specifications; Loop Limits; Power Supply - Mitel Inter-Tel 5000 Installation And Maintenance Manual

Hide thumbs Also See for Inter-Tel 5000:
Table of Contents

Advertisement

System-Wide Specifications

Important system-wide specifications appear in the following subsections.

Loop Limits

Table 4-2
and single line endpoints can be installed.
Table 4-2.
From Base Server chassis:
From DEI chassis: To a single line endpoint or playback device
driven by a SLM-8
From DEI chassis:
From an MDPM: To a single line endpoint
From an SLA: To single line endpoints or playback devices.
Supports facility code OL13C.

Power Supply

Built into the CS-52xx chassis, the 40 W power supply provides power ot the chassis and
modules. The chassis must be connected to an isolated, dedicated, 105–125 VAC, 15 A
(minimum), 57–63 Hz, single-phase commercial power source through an uninterruptible power
supply (UPS). The system power supply provides +5 VDX, 4 A output.
Built into the DEI chassis, a 100 W power supply provides power to the chassis and modules.
For universal operation, each chassis must be connected to an isolated, dedicated, 90–240
VAC, 15 A (minimum), 50/60 Hz, single-phase commercial power source through a (UPS). The
DEI power supply provides +24 VDC, 5.3 A output. For expanded applications, all required
power transformers should be plugged into appropriate power sources. For details, refer to the
equipment manufacturer's documentation.
NOTICES
Do not use an extension cord.
Do not plug any other equipment into the outlet where the UPS supporting the Base Server
or DEI is plugged-in.
Do not defeat, or leave floating, the ground wire in the AC power cord.
In addition to the system power back-up, a rechargeable battery located on the system
Processor Module backs up the database. In the event of a power failure or brownout condition,
this battery supports the module for up to one day. The battery automatically recharges when
power is restored to the module.
®
Inter-Tel
5000 Installation Manual – Issue 2.4, May 2008
identifies the maximum distances from the Inter-Tel 5000 Base Server to which digital
Loop Limits for Digital and Single Line Endpoints
Endpoints
To a single line endpoint or playback device connected to
the built-in port
To a single line endpoint or playback device driven by a
SLM-4 port
To digital endpoints
To a digital endpoint equipped with PCDPM and MDPM and
connected to DSS unit(s) or SLA
Chapter 4: Specifications
System-Wide Specifications
Port
Loop Limit
Impedance
(24 AWG)
Ω
600
2000 ft
(609 m)
REN 3.0
Ω
62
1200 ft
(366 m)
Ω
195
3800 ft
(1158 m)
Ω
800
15,560 ft
(4742 m)
Page 4-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents